2. Serial RapidIO Interface > Lookup Tables
49
Tsi578 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
5.
Program the Local LUT with the LSB values corresponding to an MSB of 0x28xx.
W 11870 0x2810
W 11874 0x3
W 11870 0x2811
W 11874 0x1
W 11870 0x2812
W 11874 0x2
W 11870 0x2813
W 11874 0x0
2.3.5
Mixed Mode of Operation
It is possible to operate a system in a mixed configured mode, with some ports in flat mode and some
ports in hierarchical mode. Each port performs destination ID lookup consistent with its configured
mode of operation.
2.3.6
Lookup Table Parity
Each entry in the lookup table is parity protected. A LUT parity error is detected in an entry when an
incoming packet causes the ingress port to read that table entry. If the ingress port detects an error, it
discards the packet and reports the error (see
). Because the packet is discarded on the ingress
port, the packet is never forwarded to the egress port and a stomp control symbol is not required when
the packet is discarded.
All LUT entries must be initialized before use to ensure that the parity bits are set appropriately.
The value of the LUT_VLD bit in the
“RapidIO Port x LUT Parity Error Info CSR” on
is unpredictable when there is a parity error in the LUT.
Содержание Tsi578
Страница 1: ...IDT Tsi578 Serial RapidIO Switch User Manual June 6 2016 Titl ...
Страница 20: ...About this Document 20 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 102: ...4 Internal Switching Fabric Packet Queuing 102 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 228: ...11 Signals Pinlist and Ballmap 228 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 504: ...B Clocking P_CLK Programming 504 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 526: ...Index 526 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...