III-2
–
The
first
settings
The first thing to do is to set the levels to correspond to you transmitter and to
the standards applied in your country.
1. Setting the levels
WARNING ! ! !
Do not make these modifications while the DEP is linked to a
transmitter. Make the settings with the TX1&2 unplugged or you could
have over modulation.
Setting the TX level
Click the « Level » icon in the central bar.
Adjust the reference levels of TX1 and TX2
Then adjust the TX output level depending on the legal modulation levels of your
country (generally 75 KHz).
IDT understood that you could need to parameter the second TX output to send
the reference 19 KHz to an RDS encoder, for example. You can, thus choose a
back-up multiplex output with this option.
If these results do not correspond to the levels measured by external equipment
consult « Calibration of your processor ».
69
Содержание Digital Encoder Plus
Страница 1: ...Digital Encoder Plus Rev 004 1 ...
Страница 6: ...Di g i t a l En c o d e r Pl u s Audio Processor User Manual 6 ...
Страница 23: ...Below the list of actions available for the Local Switches of the unit 23 ...
Страница 75: ...To calibrate the processor click Next and the next screen will appear 75 ...
Страница 77: ...The next 2 stages are similar but concern the TX2 77 ...
Страница 96: ...96 Simplified bloc diagram of the DEP ...
Страница 97: ...Examples of uses of DEP FM 97 ...