IDT Non-Transparent Mode Operation
PES16NT2 User Manual
10 - 53
April 15, 2008
Notes
Physical Layer Control and Status Registers
PC_SERDESCTL - SerDes Control (0x200)
Bit
Field
Field
Name
Type
Default
Value
Description
3:0
TXEQL
RW
0x8
Transmit Driver Equalization Level.
This field controls
the SerDes transmit driver equalization.
0x0 - (de000) de-emphasis of 0.00 dB
0x1 - (de035) de-emphasis of -0.35 dB
0x2 - (de072) de-emphasis of -0.72 dB
0x3 - (de111) de-emphasis of -1.11 dB
0x4 - (de151) de-emphasis of -1.51 dB
0x5 - (de194) de-emphasis of -1.94 dB
0x6 - (de238) de-emphasis of -2.38 dB
0x7 - (de285) de-emphasis of -2.85dB
0x8 - (de335) de-emphasis of -3.84 dB
0x9 - (de388) de-emphasis of -3.88 dB
0xA - (de444) de-emphasis of -4.44 dB
0xB- (de504) de-emphasis of -5.04 dB
0xC - (de568) de-emphasis of -5.68dB
0xD - (de638) de-emphasis of -6.38 dB
0xE - (de713) de-emphasis of -7.13 dB
0xF - (de796) de-emphasis of -7.96 dB
7:4
TXDCSF
RW
0x0
Transmit Driver Current Scale Factor.
The actual drive
current is equal to the nominal drive current selected by the
TXNDC field multiplied by the scale factor selected in this
field.
0x0 - (sf100) scale factor of 1.00
0x1 - (sf105) scale factor of 1.05
0x2 - (sf110) scale factor of 1.10
0x3 - (sf115) scale factor of 1.15
0x4 - (sf120) scale factor of 1.20
0x5 - (sf125) scale factor of 1.25
0x6 - (sf130) scale factor of 1.30
0x7 - (sf135) scale factor of 1.35
0x8 - (sf060) scale factor of 0.60
0x9 - (sf065) scale factor of 0.65
0xA - (sf070) scale factor of 0.70
0xB - (sf075) scale factor of 0.75
0xC - (sf080) scale factor of 0.80
0xD - (sf085) scale factor of 0.85
0xE - (sf090) scale factor of 0.90
0xF - (sf095) scale factor of 0.95
9:8
TXNDC
RW
0x0
Transmit Driver Nominal Drive Current.
This field selects
the SerDes transmitter nominal drive current.
0x0 - (med) 20 mA nominal drive current
0x1 -(low) 10 mA nominal drive current
0x2 -(high) 28 mA nominal drive current
0x3 -reserved
11:10
TXTERM
RW
0x0
Transmitter Termination Adjustment.
This field controls
the SerDes transmitter termination value.
0x0 - (nom) nominal transmit termination value of 50 ohms
0x1 -(m17) termination value of nominal - 17%
0x2 -(p10) termination value of n 10%
0x3 -(m15) termination value of nominal - 15%
Содержание 89HPES16NT2
Страница 14: ...DT List of Figures PES16NT2 User Manual viii April 15 2008 Notes...
Страница 20: ...IDT Register List PES16NT2 User Manual xiv April 15 2008 Notes...
Страница 32: ...IDT PES16NT2 Device Overview PES16NT2 User Manual 1 12 April 15 2008 Notes...
Страница 44: ...IDT Clocking Reset and Initialization Clock Operation PES16NT2 User Manual 2 12 April 15 2008 Notes...
Страница 50: ...IDT Link Operation PES16NT2 User Manual 3 6 April 15 2008 Notes...
Страница 62: ...IDT Power Management PES16NT2 User Manual 5 4 April 15 2008 Notes...
Страница 78: ...IDT SMBus Interfaces PES16NT2 User Manual 6 16 April 15 2008 Notes...
Страница 83: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 5 April 15 2008 Notes...
Страница 84: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 6 April 15 2008 Notes...
Страница 130: ...IDT Transparent Mode Operation PES16NT2 User Manual 9 44 April 15 2008 Notes...
Страница 284: ...IDT Non Transparent Mode Operation PES16NT2 User Manual 10 154 April 15 2008 Notes...