Location 181 to 188: Days to Auto Arm / Disarm
Location Type: Bitmap
NOTE: These locations contain both auto arm and disarm days of the week.
LED
Auto ARM Days of the Week
LED
Auto disarm Days of the Week
1
Monday
9
Monday
2
Tuesday
10
Tuesday
3
Wednesday
11
Wednesday
4
Thursday
12
Thursday
5
Friday
13
Friday
6
Saturday
14
Saturday
7
Sunday
15
Sunday
All OFF
(Arm Day Disabled)
All OFF
(Disarm Day Disabled)
Location 189: Auto Disarm
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This option sets the time the partition must disarm automatically.
Format: HHmm
Default: 0000
Valid range: 0000 to 2359
NOTE: This option must be enabled in the partition options, location 211 to 218
Plus the days to auto arm / disarm in locations 181 to 188 must be set.
Location 190: Auto Arm Delay
Location Type: Standard
This location sets the delay period for the keypad buzzer warning, before the panel auto arms. At the
completion of the Auto Arm Delay, the panel will arm. A valid user code entered during the delay period
will cancel the auto arming.
Format: mmss
Default: 0200
Valid range: 0000 to 5959
Security Options
These are the security codes that protect the panel’s programming from being changed without the
correct authorization.
Location 196: Serial Code
Location Type: Standard
This is the serial code used to link a serial device to the X-Series panel. Once the serial device is connected
and running, enter a six digit code in this location.
Default: 000000
Valid range: 000001 to 999999
Instructions
Key presses
Enter location 189
[1][8][9] [*]
Enter the partition number
[1] [*]
Enter the days for the partition to auto arm
[0] [8] [0] [0] [*]
To exit
[#]
Instructions
Key presses
Enter location 196
[1][9][6] [*]
Enter a serial code
[1] [2] [3] [4] [5] [6] [*]