IDS X-Series Training v2.7 | Programming
23
Programming
Installer Mode
Installer mode is where all settings can be changed to suit any installation requirements.
The default installer code is “9999”.
Note: Please remember to change the installer code when you have completed the installation.
(Location 197)
Exercise:
Entering the installer code.
Instructions
Key presses
Clear any previously pressed keys that may be in memory
[#]
Enter the installer code and confirm with a * (Default is 9999)
[9] [9] [9] [9] [*]
The Ready LED will begin to flash indicating installer mode
Location Definitions
A location is an area of memory that holds a value. Each location is associated to a function that the alarm
needs to operate correctly. These locations have options, other locations or different data that can be
entered, to allow for customisation depending on the property being protected and on the monitoring
company.
1.
Standard Location
A standard location is an area of memory that holds a value only.
2.
Extended Location
An extended location is a location that has multiple sub-locations within it.
3.
Bitmap
A bitmapped location is a location that has more than one option in it and each option needs to be
enabled or disabled depending on the requirements.
Programming Standard Locations
A standard location is an area of memory that holds a value only.
To program a standard location:
1.
Enter Installer mode [#] [9] [9] [9] [9] [*]
(This step is only required if you are not already in Installer mode)
2.
Then press the keys that represent the location number followed by the [*] key
3.
Now enter the data value that needs to be in the location followed by the [*] key
4.
You can enter the next location or press the [#] key to exit Installer mode.