background image

January 2020 

 

                                                                                                                                        7

Technical Manual: GigE uEye CP Rev. 2

4 Standards and directives

(only valid for devices with housing)

IDS Imaging Development Systems GmbH hereby confirms that this product has been developed, designed
and manufactured in compliance with the following European directives

·

2014/30/EU: EMC - Electromagnetic compatibility

·

2011/65/EU: RoHS - Restriction of the use of certain hazardous substances in electrical and electronic
equipment

·

Regulation (EC) No. 1907/2006 concerning the Registration, Evaluation, Authorization and Restriction of
Chemicals (REACH)

·

The CE declaration of conformity is available on the 

IDS website

.

If the product is modified or changed all approval becomes invalid. In this case the customer is responsible for
ensuring product conformity.

Product type

GigE uEye CP Rev. 2

Information for CE

EMC specifications

EN 61000-6-2
EN 61000-6-4*
EN 55032 (Class A)

Information for USA

This equipment has been tested and found to comply with part 15 of
the FCC Rules.

Class A

Information for Canada
Renseignements pour le Canada

CAN ICES-3 (A)/NMB-3(A)

Information for UL

To be compliant with the UL safety criteria GigE cameras must be
operated with indoor networks only.

UL 62368-1
CAN/CSA C22.2 No. 62368-1-14

Further information

KC (R-R-img-GIGECPR2)
ChinaRoHS EFUP 25

* Cameras are intended exclusively for use in industrial environments.

For customers in the USA

For a class A digital device:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference
at his own expense.

Name of Responsible Party

IDS Imaging Development Systems, Inc.
92 Montvale Ave., Ste 2800
Stoneham, MA 02180
U.S.A.
T: +1 781 787 0048

Содержание GigE uEye CP Rev. 2

Страница 1: ...GigE uEye CP Rev 2 IDS Imaging Development Systems GmbH Dimbacher Str 6 8 D 74182 Obersulm Germany T 49 7134 96196 0 E info ids imaging com W https en ids imaging com Technical Manual...

Страница 2: ...CP Rev 2 9 6 Mechanical specifications 10 7 Optical specifications 11 7 1 Immersion depth for lenses 11 7 2 Position accuracy of the sensor 12 8 Electrical specifications 13 8 1 Pin assignment GigE c...

Страница 3: ...nor limited by the information contained in this manual Should you require further information on this product or encounter specific problems that are not discussed in sufficient detail in the manual...

Страница 4: ...s This symbol indicates hints with useful information for better understanding and using features and functions This symbol indicates important warnings for product safety to prevent damage This symbo...

Страница 5: ...t touch the printed circuit board while it is powered Always hold the board by the edges to avoid the risk of electrostatic discharge damage For optimum ESD behavior a clearance of 4 mm from non shiel...

Страница 6: ...on de s curit LPS source puissance limit e ou ES1 PS2 Pour garantir la s curit lectrique nous recommandons l utilisation d un c ble de connexion blind ou la mise la terre du bo tier de la cam ra afin...

Страница 7: ...ation for Canada Renseignements pour le Canada CAN ICES 3 A NMB 3 A Information for UL To be compliant with the UL safety criteria GigE cameras must be operated with indoor networks only UL 62368 1 CA...

Страница 8: ...dity 20 80 relative non condensing Non condensing means that the relative air humidity must be below 100 Otherwise moisture will form on the camera surface If for example air has a relative humidity o...

Страница 9: ...ata network and the camera network should be cabled separately Therefore it is recommend connecting the cameras by a separate network card It is recommend to use Cat5e type cables The cable length of...

Страница 10: ...ch camera model can be found on our website directly at the respective camera model beneath in the Downloads tab Fig 1 GigE uEye CP Rev 2 NOTICE The camera connectors may be damaged if you install or...

Страница 11: ...into the camera flange the immersion depths are specified based on the diameter named as A B and C in the image below Beside the immersion depth also the back focal length has to be considered that m...

Страница 12: ...of the sensor 1 Fig 4 Position accuracy of the sensor 2 It cannot be guaranteed that the sensor cover glass or filter glass are absolutely parallel to each other C mount lenses can also be subject to...

Страница 13: ...utside plant 8 1 Pin assignment GigE connector RJ45 8 pin RJ45 socket Pin Designation 100BASE TX Designation 1000BASE T Fig 5 RJ45 socket camera rear view 1 Tx Bl_DA 2 Tx Bl_DA 3 Rx Bl_DB 4 Bl_DC 5 Bl...

Страница 14: ...an external source and via Power over Ethernet PoE The camera should not be supplied through both voltage sources at once as this can irreparably damage the camera Keep in mind that a voltage drop wi...

Страница 15: ...continuous IC 150 mA The digital output is galvanically isolated using an optocoupler to protect the camera and the PC against surges Only DC voltages may be applied to the digital output The output o...

Страница 16: ...January 2020 16 Technical Manual GigE uEye CP Rev 2 Fig 8 Wiring of the digital output as an open collector output Fig 9 Wiring of the digital output as an open emitter output...

Страница 17: ...ymbol Min Typ Max Unit IO voltage range VCCIO 0 3 3 V Input high range VIH 1 7 3 3 V Input low range VIL 0 3 0 8 V Input leakage current II A Output high range VOH 3 15 V Output low range VOL 0 2 V Ou...

Страница 18: ...January 2020 18 Technical Manual GigE uEye CP Rev 2 GPIO wiring as output Fig 11 GPIO wiring as output 1 Fig 12 GPIO wiring as output 2...

Страница 19: ...anual GigE uEye CP Rev 2 9 Status LED Fig 13 Status LEDs The camera has a two color LED that indicates information on the current status Camera is off no power Camera is booting Camera is ready Camera...

Страница 20: ...e DL The filter type is given at the end of the model name The following table shows an overview of the different optical filters used in IDS cameras Filter type Name Refractive index nFilter Glass ty...

Страница 21: ...or professional cleaning IDS Imaging Development Systems GmbH is not liable for any damage resulting from cleaning the filter glasses This even applies if the following instructions have been observed...

Страница 22: ...s Only add small quantities of alcohol to the wipe Never pour alcohol directly onto the camera NOTICE Never use cleaning agents containing acetone for cleaning the filter glasses Acetone may damage th...

Страница 23: ...17 H Housing version 10 I I O connector 13 Immersion depth lens 11 Immunity 7 Infrared cut filter 20 Input digital 14 L Linux 9 N Network cable 9 card 9 Network adapter 9 O Operating system Linux 9 W...

Отзывы: