Heating System Water Filling Procedure
iDRY Turbo User Manual
© 2021 iDRY, LLC
19
Main System Fill
1
Turn on water supply for the main heating system loop.
2
Connect the left lowest hose to provided hose attachments (see images)
3
Point the end of the hose towards the back of the chamber
4
From the main control screen press the “Vacuum Release” button. This will also start the drain
tank drain valves to operated on the timed interval.
5
Navigate to the “Fill” button. Press the “Help” button, then “Tools” button. Press the “Fill Water”
button. This will turn on the water fill valve.
6
Watch the hose as air then water comes out of the hose connections. Keep running until only
water is flowing. Allow water to flow for several minutes.
7
Disconnect the hose connection. Do not turn o
ff
the “fill button: until the hose is disconnected
8
Repeat procedure for the right side but use the uppermost hose.
WARNING: fill the plates and main heating system with managed water only.
Consult your local water treatment specialist to ensure you are using proper water
quality. Failure to do so can result in damage to heating system and heating plates.