SWC-2000 Command Guide
30
@GTF / @STF
Blinking time of control command button
Function
Getting
Setting
Format
@GTF, button _1 (,button _2
・・・
)
@STF, button _1, flash_1 (,button _2,
flash_2
・・・
)
Return value
@GTF, button _1, flash_1 (,button _2,
flash_2
・・・
)
@STF, button _1, flash_1 (,button _2,
flash_2
・・・
)
Parameter
button _1-16: Control command button
0 = All control command button
1 to 16 = Control command button 1 to Control command button 16
flash_1-16: Blinking time
-1 = Links during control command execution, 0 = Not blink [Default]
1 to 1000 = 1 sec. to 1000 sec.
Example
@GTF,6
@GTF,6,-1
Getting the blinking time of Control
command button 6
Blinks during control command execution
@STF,4,5
@STF,4,5
Setting the Control command button 4 to
blink 5 seconds after control command
execution starts
Completed
Remarks
-
@GGL / @SGL
LAST BUTTON MEMORY (Start-up lighting by group)
Function
Getting
Setting
Format
@GGL, group _1 (,group _2
・・・
)
@SGL, group _1, memory _1 (,group _2,
memory _2
・・・
)
Return value
@GGL, group _1, memory_1 (,group _2,
memory _2
・・・
)
@SGL, group _1, memory _1 (,group _2,
led_2
・・・
)
Parameter
group _1-8: Group of control command buttons
0 = All groups
1 to 8 = Group 1 to Group 8
memory _1-8: Lighting status of control command buttons during powered on
0 = Does not light [Default]
1 = The last lighting status will be maintained
Example
@GGL,5
@GGL,5,0
Getting the lighting status of Group 5
’s
control command buttons during powered
on
Not light
@SGL,2,1
@SGL,2,1
Setting Group 2
’s control command
buttons to be the last lighting status
during powered on
Completed
Remarks
-