5.7  Precautions 

■  Installation 
<Electrostatic discharge failure of connector> 

●  In order to connect cables to the OPF-H1000 or to devices connected to the OPF-H1000, remove 

static electricity by touching grounded metal such as racks before handling single cables. Otherwise it 

may cause a malfunction.   

<Others> 

●  Do not place the transmitter on top of the receiver and vice versa. 
●  Do not block vent holes. Keep enough space (3 cm/1.18 inches or more) around the product. 
●  Do not install the OPF-H1000 in closed space. 

If you have to install the product to an EIA rack mount in closed space, add a ventilation to keep the   

ambient temperature of 40 degrees C/104 degrees F or less. (Exception: Installing to IDK’s Quarter      

rack, RM-42HQ) If inadequately vented, the life of parts may be shortened and operations may be     

affected.   

 
■  Operating precautions 

●  Use HDMI signal I/O cables less than 5 m/16.4 feet whose pins are assigned appropriately. This 

extension distance cannot be longer even if connecting to a device that has a compensation circuit     

for digital cables.   

●  If connecting the OPF-H1000 to a device that is in an extremely bad condition, video image may be   

interrupted.   

●  The OPF-H1000 will transmit signals using DVI mode only if the resolution of the input signal 

resolution is   

set to WUXGA. However, some source devices can still use HDMI mode for WUXGA resolution if     

supported.   

●  Since the OPF-H1000 transmits input signals without compressing or processing, signals are 

transmitted   

in 24bits/pixel (8 bits/component) even to sink devices that support Deep Color formats. 

●  Clean the connector ends of the fiber optic with a cleaner before inserting. 
●  Plug the dust cap to the SFP module when you do not connect the fiber optical cable. For connectors 

of the fiber optical cable, use the cap. 

●  Do not plug or unplug the SFP module or fiber optical cable when the product is turned on. 
●  Before turning on/off the OPF-H1000, turn off or mute the connected devices first to avoid a noise 

sound. 

●  Make sure not to exceed the allowable bend radius of fiber optical cable that are determined based on 

each fiber specifications. Otherwise, transmission loss may occur.   

●  The maximum transmission distance is the value acquired from the following conditions: 

- the recommended fiber is used, 

- no connection through the path way, and   

- the allowable bend radius is not exceeded. 

●  Do not use the SFP module of the OPF-H1000 for other devices or connect fiber optical cable that are   

connected to other devices to the SFP module of the OPF-H1000. It may cause malfunctions of the 

SFP module. The maximum receiving optic power used for the OPF-H1000 is 0 dBm. 

●  The OPF-H1000 can be connected to the optical I/O slot board of the FDX series but not to other OPF   

series. 

 

 

Содержание OPF-TH1000-A

Страница 1: ...this User s Guide fully and carefully before using it and keep this manual beside the OPF H1000 IDK Corporation POWER SIGNAL POWER SIGNAL RX OPTICAL Rx for HDMI OPF RH1000 A DC 5V 2A FG OPTICAL OUTPU...

Страница 2: ...ace and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries All other company and product names mentioned in this manual are either reg...

Страница 3: ...nual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct...

Страница 4: ...al injury if the warning is ignored or the equipment is handled incorrectly Indicates the presence of a hazard that may cause minor personal injury or property damage if the caution is ignored or the...

Страница 5: ...ty damage Set the power plug in a convenient place to unplug easily You can easily unplug in case of any extraordinary failure or abnormal situation and it also helps for unplugging when you do not us...

Страница 6: ...or dusty place If the product is placed near humidifiers or dusty area it may cause fire or electric shock Do not block the vent holes If ventilation slots are blocked it may cause fire or failure due...

Страница 7: ...Cascade connection 14 5 2 HDMI input output cable 14 5 3 Fiber optical cables for long distance transmission 15 5 4 SFP Small Form factor Pluggable module 15 5 5 Audio Transmission 16 5 6 RS 232C Tran...

Страница 8: ...PF TH1000 and OPF RH1000 set Transmitter OPF TH1000 OPF TH1000 main unit x 1 AC adapter with screw type lock 1 2 m 3 94 feet x 1 Cable clamp x 1 Receiver OPF RH1000 OPF RH1000 main unit x 1 AC adapter...

Страница 9: ...nto the fiber optic cables themselves Plug the attached dust caps into the optical transceivers when the fiber cable is unplugged The OPF H1000 is a transmitter and receiver set that enables HDMI sign...

Страница 10: ...hile that of multimode fiber is approximately 50 m or 62 5 m Singlemode fiber is suited for long distance transmission Multimode fiber is not suited for those transmissions but it is inexpensive OM3 O...

Страница 11: ...optical cables to connect OPF TH1000 transmitter and OPF RH1000 receiver AC adapter connector Connector for the supplied AC adapter Cable fixing hole Hole for the attached cable clamp RS 232C port Po...

Страница 12: ...he supplied cord clamp RS 232C connector Connector for D sub 9 pin Audio output connectors Output connector for audio signals Those audio signals were not de embedded Frame ground Ground for indoor gr...

Страница 13: ...or 5 Connect the DC plug of the supplied AC adapter to the DC jack Make sure to lock the DC jack and plug using the screw type locking mechanism Note After all connections are established plug the AC...

Страница 14: ...ion is not available in the following cases repeater that only supports HDCP pass through such as some switchers boosters and so on is included another set of OPF TH RH1000 IDK s fiber optic cable ext...

Страница 15: ...fiber has two fibers and two connectors The duplex fiber cable is recommended for OPF H1000 but signals can be transmitted using two simplex fiber cables LC connector One of connectors for fiber optic...

Страница 16: ...ifications of each connected device Connection with other IDK products Cross cables Connection with a computer Cross bales IDK Product OPF TH1000 A Transmitter OPF RH1000 A Receiver Cross cable Cross...

Страница 17: ...input signal resolution is set to WUXGA However some source devices can still use HDMI mode for WUXGA resolution if supported Since the OPF H1000 transmits input signals without compressing or process...

Страница 18: ...F RH1000 A User s Guide 18 Notes Supply power to the AC adapter only after all connections are completed See 7 Troubleshooting if video image is not displayed appropriately on the monitor connected to...

Страница 19: ...I cable to the OPF H1000 1 Pull up the part pointed by the short arrow and separate the bar and ring parts 2 Pass the HDMI cable through the ring 3 Insert the bar to the OPF H1000 as shown below 4 Att...

Страница 20: ...N C 15 SCL 16 SDA 17 DDC CEC Ground 18 5 V Power 19 Hot Plug Detect N C No connection 6 2 RS 232C pin assignments D sub9 pin locations Male 1 5 RS 232C connector 6 9 RS 232C connector Pin assignments...

Страница 21: ...n No connection Pin assignments when connected to an IDK product Note Make sure to use a cross cable RD TD N C N C N C N C GND RTS CTS Pin No 1 3 2 4 6 5 7 9 8 Signal TD RD N C N C N C N C GND RTS CTS...

Страница 22: ...monitor Audio format Multi linear PCM up to 8 channels Analog audio input 5 3 5 mm Stereo mini jack L R Unbalanced signal Input impedance 11 k Reference level 10 dBu Max input level 3 dBu Analog audi...

Страница 23: ...er OPF RH1000 A MM Singlemode fiber Transmitter OPF TH1000 A SM SFP module for singlemode is mounted Receiver OPF RH1000 A SM 1 HEC and ARC are not supported 2 Use an HDMI cable that is 5 m 16 4 feet...

Страница 24: ...re there no loose connections Are cables that are appropriate to this device being used Are signal specifications of connected devices matched to each other Are settings of the sink device correct Are...

Страница 25: ...00 0765 Email idk_eng idk co jp URL http www idk co jp en index html Product information Support Arvanics Corporation 3 8 3 3F Yamato Higashi Yamato shi Kanagawa pref 242 0017 JAPAN TEL 81 46 259 6920...

Отзывы: