MSD-54 SERIES User
’s Guide
90
8.6 Input Timing Settings
The MSD continuously monitors input signals. When signals input from analog input (IN6 to IN9) changes, the
MSD loads the optimal table from the built-in tables and converts the signals. However, if signals which are
not registered in the MSD tables are input or if part of the output video is cut off by using the standard table
registered in the MSD, set the input timing manually. You can check if the input signals are registered in the
MSD in
”. Normally, it is set automatically by the operations in “
”, but if the automatic setup fails, you can set it manually.
For digital inputs, IN1 to IN5, you do not need to set the input timing, but if part of the video is cut off, adjust
the input timing finely.