MSD-402 User’s Guide
78
You can set the speaker configuration of multi channel audio.
This menu is valid only if you select “INTERNAL EDID” for “
” and you select a resolution other
than “UNUSED” for “
8.10.3 Input resolution for AV devices
”.
If you select “AUTO” for the setting mode and set the number of speakers, the speaker configuration will be
set to the default setting that is shown in “
[Table 8.15] Default speaker configuration
”.
To change the default configuration, set the mode to “MANUAL” and set each speaker to ON/OFF individually.
The number of speakers currently selected is displayed on “NUMBER”.
If the number of speakers exceeds the available value, the “DATA INVALID” message is displayed and the
settings will not be applied.
Click the “SET” button to open the dialog box and click the “OK” button to renew the EDID settings.
If the number of speakers you specified exceeds stable value, the dialog box gives you a notice and cannot
set.
8.10.7 Copying EDID
Menu EDID
→
MONITOR EDID COPY
Setting value COPY EDID No.1 and No.2
You can load and register the sink device EDID to the MSD.
Up to eight EDID can be registered.
Click the “COPY” button to open the dialog box and click the “OK” button to copy the EDID.
If no sink device is connected to the selected output channel, the operation cannot be executed.