FDX-S Series User Guide
60
10.4.9 Sink device EDID check
Menu
Top
→
OUTPUT SETTINGS
→
EDID ERR. OUTPUT MODE
Setting for
OUT01 to OUTn
Setting value
[Table 10.5] Sink device EDID check
Setting value
Description
OFF [Default]
In case of error, treated as DVI
ERROR1
In case of error, treated as HDMI without SCDC
ALWAYS1
Treated as HDMI without SCDC all the time
ERROR2
In case of error, treated as HDMI with SCDC
ALWAYS2
Treated as HDMI with SCDC all the time
The FDX-S gets EDID from the sink device and determines if the sink device is an HDMI device or DVI
device. However, if the FDX-S cannot get EDID for some reasons, problems such as no audio output and
the like may occur.
“ERROR2” and “ALWAYS2” are only for FDX-SIV4UT/FDX-SIV4UH boards.
Notes:
・
This setting is applied when HDMI signal is input and
” is set to a format other than
DVI.
・
If setting this menu to a value other than the default (OFF), set
” to a supported
resolution other than External EDID.
【
【
10.4.10 Hot plug ignoring duration
Menu
Top
→
OUTPUT SETTINGS
→
HOTPLUG MASK
Setting for
ALL, OUT01 to OUTn
Setting value OFF [Default], 2Sec to 15Sec
You can set the time for ignoring the video output request signals sent from the sink device.
If the request signals are repeated in a short cycle, the FDX-S processes video output from the first cycle.
As a result, video may not be output. This problem can be solved by setting the ignoring time.