FDX-08 User Guide
62
8.7.2 Copying EDID [EDID SAVE]
You can store the sink device EDID in the FDX. The stored EDID can be treated as internal EDID by
registering the EDID.
【
See: 8.7.1 EDID resolution [EDID DATA]
Menu
EDID → EDID SAVE
Setting for
Each copied EDID stored area (1[xxx] to 4[xxx])
Setting value
OUT1[xxx]
*1
to OUT8[xxx]
*1
: OUT1 to OUT8 EDID [Default] 05:1080p (59.94/60)
*2
*1
“xxx” : Vendor code of the saved EDID
*2
05 : 1080p (59.94/60) is stored in all stored area as factory default
Notes:
・
Press the SET key to apply the setting.
・
Only channels of output board can be selected in this menu.
8.7.3 EDID loading output channel [EDID EXTERNAL CH]
You can set the output connector to be loaded when the EDID type is set to “EXTERNAL”.
【
See: 8.7.1 EDID resolution [EDID DATA]
Menu
EDID → EDID EXTERNAL CH
Setting for
Each input connector (IN1 to IN8)
Setting value
OUT1 to OUT8: EDID loading output channel OUT1 to OUT8 [Default] OUT1
Notes:
・
Press the SET key to apply the setting.
・
This menu is valid if you select “00” for the resolution of EDID.
・
Only channels of input board or output board can be selected in this menu.
Channels in which an SDI input board cannot be selected.