DFS-01UHD/DFS-01HD Command Guide
42
@GST
Internal temperature
Getting
Command @GST
Response @GST, temp, status
Parameter
temp: Internal temperature value
The value of temperature x 100
e.g.) 38.75°C:
3875
status: Internal temperature status
0 = No problem detected, 1 = Problem detected
Getting
example
Command
Response
@GST
@GST,3425,0
Description Getting the internal temperature
Temperature: 34.25°C; status: Normal
Remarks
-
@GFS
Cooling fan status
Getting
Command @GFS
Response @GFS, rpm, status
Parameter
rpm: Cooling fan rotation speed
status: Cooling fan rotations
0 = No problem detected, 1 = Problem detected
Getting
example
Command
Response
@GFS
@GFS,3720,0
Description Getting the cooling fan rotations
All cooling fan speed: 3720 rpm; status: Normal
Remarks
-
@GPS
Voltage status
Getting
Command @GPS
Response @GPS, voltage, status
Parameter
voltage: Power supply voltage = The power supply voltage x 1000
e.g.) 12.210 V: 12210
status: Voltage status
0 = No problem detected, 1 = Problem detected
Getting
example
Command
Response
@GPS
@GPS,12210,0
Description Getting the voltage status
Voltage: 12.210 V; status: Normal
Remarks
-