![Idex Hale Sam Скачать руководство пользователя страница 116](http://html2.mh-extra.com/html/idex/hale-sam/hale-sam_operation-installation-maintenance-manual_3699854116.webp)
100
C.
On Pump Controller, touch Export Datalogger command.
Saving file to the USB
stick …
appears below command.
D.
Wait for
Data log file has been saved to the USB stick.
to appear below com-
mand.
NOTES
The save may take several minutes to complete. A comma separated values file named
LogFile_MatrixDisplay.csv appears on the USB stick when the transfer completes.
If a data log file already exists on the USB stick it is overwritten by the new file.
If
There was a problem saving to the USB stick!
appears the file transfer failed. Cycle
the SAM system power and repeat the entire procedure using a different USB stick.
E.
Disconnect USB stick.
F.
Touch Back To Previous Screen icon (see Table 3, page 14).
6.3.4
Governor Operations From The Pump Controller
The SAM system must be in Manual Mode to use a governor screen. When the SAM system is
placed in Manual Mode the default governor mode is PSI MODE. Perform Steps A and B in para-
graph 6.3.2, Manual Mode (page 82), to enter SAM Manual Mode.
6.3.4.1
Changing Governor Modes
When the SAM system exits Auto Mode, the governor is placed in PSI Mode (see Figure 41,
page 30). The exception to this default is if the SAM system is equipped with an optional
SmartCAFS foam system. If CAFS/FOAM was active when Auto Mode was exited the governor is
placed in RPM Mode (see Figure 48, page 33).
The Pump Controller home screen is the ONLY screen that a governor screen is displayed, and
governor operations can ONLY be performed from a governor icon group. The current governor
mode (MODE PSI or MODE RPM) is displayed on the upper most button of the displayed icon
group. The governor mode can ONLY be toggled between the two modes (PSI or RPM) so it is ir-
relevant which governor mode is the current mode, to change modes, perform the following.
A.
If Pump Controller home screen is NOT displayed, navigate to home screen as fol-
lows.
In System Options and Tab Button Area (see Figure 32, page 30), touch
icon.
Pump Controller home screen is displayed.
B.
Touch the governor mode button (
or
).
The governor mode is toggled to the opposite mode.
6.3.4.2
Activating A Preset
Both governor mode screens provide the selection of up to two [2] presets (pressure set points
for PSI Mode or engine speed set points for RPM Mode). Presets are active identically for either
mode. Perform the following to activate a governors mode preset.
A.
Touch desired preset button.
B.
Drag button to target as follows.