94
Figure 111. Activating A CAFS Quickset
C.
Drag Quickset button to target (PUSH TO PUMP or ADD LINE).
D.
Release Quickset button (remove finger from screen).
The SmartCAFS system powers on and activates preset #1. The associated concentration of
foam solution is discharged.
Operate CAFS from the SmartCAFS Control Display from this point, reference UV SmartCAFS In-
stallation and Operation Manual (P/N FSG-MNL-00157).
6.3.3.4.2
Activating A SmartCAFS Preset
IF THE DISCHARGE DOES NOT ACTIVATE VERIFY THE CAFS SYSTEM PRESETS (PRESET
1 FOR CAFS, PRESET 7 FOR FOAM ONLY ON THE SMARTCAFS DISPLAY) CONFIGURA-
TION MATCHES THE SAM CONFIGURATION. (SAM WILL ONLY ACTIVATE MATCHING
CONFIGURATIONS–WET, MED, OR DRY.) IF THE CONFIGURATIONS DO NOT MATCH, OP-
ERATE SAM MANUALLY TO OPEN THE VALVE USING THE SAM CONTROL CENTER. THEN
OPERATE THE CAFS SYSTEM FROM THE SMARTCAFS DISPLAY.
To activate a SmartCAFS preset, perform the following.
A.
Select appropriate foam concentrate tank. (Reference FSG-MNL-00157.)
B.
Touch PUSH TO PUMP (or ADD LINE) target, to display SELECT DISCHARGE
screen. See Figure 112.
C.
Touch desired discharge (valve) button. (All CAFS available discharges are la-
beled with one of the following words: DRY, MED, WET, or FOAM.) Valve X screen
displays. See Figure 112.