SNIB3 Quick Installation Guide
S3
1
Addr
S4
S5
S6
S7
S8
OFF
OFF
OFF
OFF
OFF
ON
2
OFF
OFF
OFF
OFF
ON
OFF
3
OFF
OFF
OFF
OFF
ON
ON
4
OFF
OFF
OFF
ON
OFF
OFF
5
OFF
OFF
OFF
ON
OFF
ON
6
OFF
OFF
OFF
ON
ON
OFF
7
OFF
OFF
OFF
ON
ON
ON
8
OFF
OFF
ON
OFF
OFF
OFF
9
OFF
OFF
ON
OFF
OFF
ON
10
OFF
OFF
ON
OFF
ON
OFF
11
OFF
OFF
ON
OFF
ON
ON
12
OFF
OFF
ON
ON
OFF
OFF
13
OFF
OFF
ON
ON
OFF
ON
14
OFF
OFF
ON
ON
ON
OFF
15
OFF
OFF
ON
ON
ON
ON
16
OFF
ON
OFF
OFF
OFF
OFF
17
Addr
OFF
ON
OFF
OFF
OFF
ON
18
OFF
ON
OFF
OFF
ON
OFF
19
OFF
ON
OFF
OFF
ON
ON
20
OFF
ON
OFF
ON
OFF
OFF
21
OFF
ON
OFF
ON
OFF
ON
22
OFF
ON
OFF
ON
ON
OFF
23
OFF
ON
OFF
ON
ON
ON
24
OFF
ON
ON
OFF
OFF
OFF
25
OFF
ON
ON
OFF
OFF
ON
26
OFF
ON
ON
OFF
ON
OFF
27
OFF
ON
ON
OFF
ON
ON
28
OFF
ON
ON
ON
OFF
OFF
29
OFF
ON
ON
ON
OFF
ON
30
OFF
ON
ON
ON
ON
OFF
31
OFF
ON
ON
ON
ON
ON
32
ON
OFF
OFF
OFF
OFF
OFF
33
ON
OFF
OFF
OFF
OFF
ON
34
ON
OFF
OFF
OFF
ON
OFF
35
ON
OFF
OFF
OFF
ON
ON
36
ON
OFF
OFF
ON
OFF
OFF
37
ON
OFF
OFF
ON
OFF
ON
38
ON
OFF
OFF
ON
ON
OFF
39
ON
OFF
OFF
ON
ON
ON
40
ON
OFF
ON
OFF
OFF
OFF
41
ON
OFF
ON
OFF
OFF
ON
42
ON
OFF
ON
OFF
ON
OFF
43
ON
OFF
ON
OFF
ON
ON
44
ON
OFF
ON
ON
OFF
OFF
45
ON
OFF
ON
ON
OFF
ON
46
ON
OFF
ON
ON
ON
OFF
47
ON
OFF
ON
ON
ON
ON
48
ON
ON
OFF
OFF
OFF
OFF
49
ON
ON
OFF
OFF
OFF
ON
50
ON
ON
OFF
OFF
ON
OFF
51
ON
ON
OFF
OFF
ON
ON
52
ON
ON
OFF
ON
OFF
OFF
53
ON
ON
OFF
ON
OFF
ON
54
ON
ON
OFF
ON
ON
OFF
55
ON
ON
OFF
ON
ON
ON
56
ON
ON
ON
OFF
OFF
OFF
57
ON
ON
ON
OFF
OFF
ON
58
ON
ON
ON
OFF
ON
OFF
59
ON
ON
ON
OFF
ON
ON
60
ON
ON
ON
ON
OFF
OFF
61
ON
ON
ON
ON
OFF
ON
62
ON
ON
ON
ON
ON
OFF
63
ON
ON
ON
ON
ON
ON
Network Address Settings (S3 - S8 in Switch Bank 3)
S3
S4
S5
S6
S7
S8
1900 Carnegie Ave., Bldg. B
Santa Ana, CA 92705-5520
(949) 250-8888
www.identiv.com
Installations with NET*MUX4s support up to 63 controllers. Installations without NET*MUX4s are
limited to 16 controllers, which can have any address in the range 1-63. Where possible, limit your
multi-drops to 16 units for optimum speed and performance. Even at 9600 bps, two 16-unit
configurations outperform one 32-unit configuration.
For more information, see the
SNIB3 topics in the
DIGI*TRAC
Design and Installation Guide
.
To mount the SNIB3 expansion board:
1.
Turn all system power off: remove the connector for the standby battery, disconnect the AC
power connector or the power supply fuse.
2.
Install the new SNIB3 board into the upper left corner of the enclosure using the supplied
screws. If there are additional expansion boards to install, install them first using the supplied
standoffs. Install the SNIB3 board last so that it is at the top of the stack.
3.
Connect the EBIC5 connector. Reconnect the AC power connector (or power supply fuse), then
reconnect the standby battery connector. The controller board's yellow test LED should light;
the other lights go through a start up sequence. When the sequence is complete, the yellow test
LED goes out and the other lights stabilize.
4.
If required, connect an RJ-45 network cable to the SNIB3 Ethernet connector.
Mounting the Board
If a MEB/BE, MEB/CE, or MEB/CB board is installed, do
not remove it. Removing any of these boards will cause
the controller to malfunction and requires a system
cold start. This will erase all additional information in
their memory and requires complete system download.
!
4
Revised 6/20/2016
Connect
screws to
the board.
If you stack boards, make sure the
SNIB3 is on top of the stack, so you
can wire the board, configure its DIP
switches, and view its status LEDs.
1