Wiring Recommendations / Recommandations de câblage
IDEMIA recommends using a gauge AWG20 for 12V power supply when POE supply is
not used.
The voltage specified is the one measured on the product block connector: 12V-24V (-
15% / +10%)
For information, this table shows the maximum drop voltage observed on the terminal
MorphoWave
TM
OEM:
Gauge
AWG
Diameter
(mm)
Maximum
drop
voltage
@ 1m (V)
Maximum
drop
voltage
@ 5m (V)
Maximum
drop
voltage
@ 10m
(V)
20
0.81
0.03
0.17
0.33
22
0.64
0.05
0.26
0.53
24
0.51
0.08
0.42
0.84
Drop voltage = loss of power due to wire resistance and its length: V2 = V1 – Drop
voltage
IDEMIA recommande d'utiliser une jauge AWG20 pour une alimentation 12V lorsque
l'alimentation POE n'est pas utilisée.
La tension spécifiée est celle mesurée sur le connecteur du produit: 12V-24V (-15% /
+10%)
Pour information, ce tableau montre la chute de tension maximale observée sur le
terminal MorphoWave
TM
OEM:
Jauge
AWG
Diamètre
(mm)
Chute de
tension
Maximum
@ 1m (V)
Chute de
tension
Maximum
@ 5m (V)
Chute de
tension
Maximum
@ 10m (V)
20
0.81
0.03
0.17
0.33
22
0.64
0.05
0.26
0.53
24
0.51
0.08
0.42
0.84
V1
V2
L