2 Word Write Command
12-10
WindO/I-NV4 User’s Manual
■
Set
■
Move
■
Momentary
■
Add, Sub, Multi, Div, Mod, OR, AND, XOR
Writes a fixed value to a word device when the
trigger condition is satisfied.
State of condition
Data written
Write
Action
Write
Value
Value
Condition
Condition
Condition
Condition
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Writes the value of source device address to the
destination word device when the trigger
condition is satisfied.
State of condition
Data written
Write
Action
Write
Value in
device address
Value in
device address
Condition
Condition
Condition
Condition
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Writes a fixed value of ON Data to a word device
when the trigger condition is satisfied.
Writes a fixed value of OFF Data to a word device
when the trigger condition is no longer satisfied.
State of condition
Data written
Write
Action
OFF Data
Write
ON Data
Write
OFF Data
Write
ON Data
Condition
Condition
Condition
Condition
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Performs arithmetic on the value of source device
address and a fixed value, or a value of device
address and writes the result to a word device
when the trigger condition is satisfied.
Example: Add (Addition)
When the trigger condition is satisfied,
the value in the
Source 1
is added to
the value in
Source 2
and the result is
written to the word device.
State of condition
Data written
Action
Result
Arithmetic operation
↓
Write
Result
Arithmetic operation
↓
Write
Condition
Condition
Condition
Condition
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
State of condition
Data written
Action
Result
Result
Addition
↓
Write
Addition
↓
Write
Condition
Condition
Condition
Condition
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Satisfied
Satisfied
Satisfied
Not satisfied
Not satisfied
Not satisfied
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...