3 Project Settings Dialog Box
4-66
WindO/I-NV4 User’s Manual
3.12 Web Server Tab
The
Web Server
tab configures the MICRO/I's Web Server function. For details, refer to Chapter 28 “1 Web Server
■
Use System Web Page
Select this check box to access the Remote Control page, Remote Monitor page or System Detailed Information page
of MICRO/I from a web browser terminal.
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
(Data Type)
Remote Control and Monitoring
Select the functions allowed when accessing the MICRO/I from a web
browser terminal from the following.
This option can only be set when
Use System Web Page
is selected.
Enable Remote Control and Monitor: Displays a screenshot of the screen displayed on the MICRO/I. You can also
control the MICRO/I being monitored by clicking on the displayed screenshot.
Enable Remote Monitor only:
Displays a screenshot of the screen displayed on the MICRO/I.
Disable:
Displays only the detailed system information page.
Go back to System Information if operation is not performed for the following period:
Select this check box to automatically return to the homepage when no
action is performed in the Remote Control page or Remote Monitor page for
a specified time. Specify the time until the page returns to the System
Information page following the last action performed in the Remote Control
page or the Remote Monitor page.
This can only be set when
Enable Remote Control and Monitor
or
Enable Remote Monitor only
is selected.
(Data Type):
Select the data type for which the System Information
page return time is specified. Units are minutes.
Value:
Use a constant value (1 to 60).
Device Address: Use a value of device address.
Click
to display the Tag Editor. For the device
address configuration procedure, refer to Chapter 2
“5.1 Device Address Settings” on page 2-70.
:
If
Device Address
is selected for (Data Type), note the following points:
• If the value of device address is set to 61 or higher, it will be treated as 60 minutes.
• Once a network connection is established between the web browser and the MICRO/I, the timeout period
cannot be changed. The timeout period needs to be set in Device Address before a web browser access
to the MICRO/I.
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...