4 Script Definition Method
20-26
WindO/I-NV4 User’s Manual
Data comparison and copy
Character string operation
Only internal devices can be specified as an argument for character string operation function.
Termination character NULL (0x00) is treated as end of character string when character string is handled. Also,
termination character NULL is not included in the length of the character string.
Function
Format
Description
Data comparison
MEMCMP(
,
,
)
: Beginning device address of comparison target 1
: Beginning device address of comparison target 2
: Range of comparison (in words)
Values of device address
for
words and values of
device address
for
words are compared.
1 is returned if all the values of device addresses match, and 0 is
returned if any of the value does not match.
Specified range is compared in word unit, and result is returned.
Data copy
MEMCPY(
,
,
)
: Beginning device address of copy source
: Beginning device address of copy target
: Range of copy (in words)
Values of device address from
for
words are copied
to
for
words respectively.
Specified range is copied in word unit.
Function
Format
Description
Character string
copy
STRCUT(
,
,
,
)
: Beginning device address of copy target
: Beginning device address containing copy source
character string
: Start location of copy (0-127)
: Number of characters to copy (1-128)
From the character string starting from
, character
string from
bytes forward for
characters are
stored into
for
characters.
Character number
count
STRLEN(
)
Number of characters for character string starting from
is returned.
Character string
concatenation
STRCAT(
,
)
To the character string starting from
, the character
string starting from
is concatenated, and
is
returned to beginning.
Character string
search
STRSTR(
,
)
From the character string starting from
, character
string starting from
is searched, and location found
(number of characters from beginning -1) is returned.
Maximum number for character string to search is 128
characters.
a
b
c
a
b
c
a
c
b
c
a
b
c
a
b
c
a
c
b
c
a
b
c
d
a
b
c
d
b
c
d
a
d
a
a
a
b
a
b
a
a
b
a
b
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...