3:
M
OVE
I
NSTRUCTIONS
3
‐
10
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
IBMV
(Indirect
Bit
Move)
Applicable
CPU
Modules
Valid
Devices
For
the
valid
device
address
range,
see
pages
and
(
Basic
Vol.).
Internal
relays
M0
through
M2557
can
be
designated
as
D1.
Special
internal
relays
cannot
be
designated
as
D1.
When
T
(timer)
or
C
(counter)
is
used
as
S2
or
D2,
the
timer/counter
current
value
(TC
or
CC)
is
read
out.
Make
sure
that
the
last
source
data
determined
by
S1+S2
and
the
last
destination
data
determined
by
D1+D2
are
within
the
valid
device
range.
If
the
derived
source
or
destination
device
is
out
of
the
valid
device
range,
a
user
program
execution
error
will
result,
turning
on
special
internal
relay
M8004
and
ERR
LED
on
the
CPU
module.
Either
source
device
S2
or
destination
device
D2
does
not
have
to
be
designated.
If
S2
or
D2
is
not
designated,
the
source
or
destina
‐
tion
device
is
determined
by
S1
or
D1
without
offset.
Examples:
IBMV
Source
device
S1
and
destination
device
D1
determine
the
type
of
device.
Source
device
S2
and
destination
device
D2
are
the
offset
values
to
determine
the
source
and
destination
devices.
As
a
result,
when
input
I0
is
on,
the
ON/OFF
status
of
internal
relay
M15
is
moved
to
output
Q44.
FC5A
‐
C10R2/C/D
FC5A
‐
C16R2/C/D
FC5A
‐
C24R2/C/D
FC5A
‐
D16RK1/RS1
FC5A
‐
D32K3/S3
FC5A
‐
D12K1E/S1E
X
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1
(Source
1)
Base
address
to
move
from
X
X
X
X
— —
X
0
or
1
1
‐
99
S2
(Source
2)
Offset
for
S1
X
X
X
X
X
X
X
0
‐
65535
—
D1
(Destination
1)
Base
address
to
move
to
—
X
X
— —
X
—
1
‐
99
D2
(Destination
2)
Offset
for
D1
X
X
X
X
X
X
X
0
‐
65535
—
S1
+
S2
D1
+
D2
When
input
is
on,
the
values
contained
in
devices
designated
by
S1
and
S2
are
added
to
determine
the
source
of
data.
The
1
‐
bit
data
so
determined
is
moved
to
destination,
which
is
determined
by
the
sum
of
values
contained
in
devices
desig
‐
nated
by
D1
and
D2.
IBMV
S1(R)
*****
S2
*****
D1(R)
*****
D2
*****
REP
**
S1
–
M10
I0
IBMV
S2
D10
D1
–
Q30
SOTU
REP
D2
C5
M10
D10
Q30
+
C5
M27
M10
M17
M20
M15
5th
from
M10
Q47
Q30
Q37
Q40
12th
from
Q30
Q44
If
the
value
of
data
register
D10
designated
by
source
device
S2
is
5,
the
source
data
is
determined
by
adding
the
offset
to
internal
relay
M10
designated
by
source
device
S1.
If
the
current
value
of
counter
C5
designated
by
destination
device
D2
is
12,
the
destination
is
determined
by
adding
the
offset
to
output
Q30
designated
by
destination
device
D1.
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...