![IDEC MICROSmart FC5A Series Скачать руководство пользователя страница 210](http://html.mh-extra.com/html/idec/microsmart-fc5a-series/microsmart-fc5a-series_user-manual_617369210.webp)
16:
I
NTELLIGENT
M
ODULE
A
CCESS
I
NSTRUCTIONS
16
‐
4
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
STPA
READ
(Stop
Access
Read)
Note:
STPA
READ
and
STPA
WRITE
instructions
can
be
used
64
times
in
a
user
program.
When
more
than
64
STPA
READ
and
STPA
WRITE
instructions
are
used
in
a
user
program,
the
excess
instructions
are
not
executed
and
error
code
7
is
stored
in
the
data
register
designated
as
STATUS.
Applicable
CPU
Modules
Valid
Devices
(Stop
Access
Read)
For
the
valid
device
address
range,
see
pages
and
(
Basic
Vol.).
DATA:
Specify
the
first
device
address
to
store
the
data
read
from
the
intelligent
module.
Internal
relays
M0
through
M2557
can
be
designated
as
DATA.
Special
internal
relays
cannot
be
designated
as
DATA.
When
T
(timer)
or
C
(counter)
is
used
as
DATA
for
Stop
Access
Read,
the
data
read
from
the
intelligent
module
is
stored
as
a
preset
value
(TP
or
CP)
which
can
be
0
through
65535.
All
data
registers,
including
special
data
registers
and
expansion
data
registers,
can
be
designated
as
DATA.
STATUS:
Specify
a
data
register
to
store
the
operating
status
code.
Data
registers
D0
‐
D1999
and
D10000
‐
D49999
can
be
desig
‐
nated
as
STATUS.
Special
data
registers
and
expansion
data
registers
cannot
be
designated.
For
status
code
description,
see
SLOT:
Enter
the
slot
number
where
the
intelligent
module
is
mounted.
A
maximum
of
seven
intelligent
modules
can
be
used.
ADDRESS:
Specify
the
first
address
in
the
intelligent
module
to
read
data
from.
BYTE:
Specify
the
quantity
of
data
to
read
in
bytes.
The
STPA
READ
instruction
cannot
be
used
in
an
interrupt
program.
If
used,
a
user
program
execution
error
will
result,
turning
on
spe
‐
cial
internal
relay
M8004
and
the
ERR
LED
on
the
CPU
module.
If
a
STPA
READ
instruction
is
programmed
between
MCS
and
MCR
instructions,
the
STPA
READ
instruction
is
executed
when
the
CPU
module
is
stopped
regardless
whether
the
input
condition
for
the
MCS
instruction
is
on
or
off.
For
MCS
and
MCR
instructions,
see
page
(Basic
Vol.)
.
Valid
Data
Types
FC5A
‐
C10R2/C/D
FC5A
‐
C16R2/C/D
FC5A
‐
C24R2D
FC5A
‐
C24R2/C
FC5A
‐
D16RK1/RS1
FC5A
‐
D32K3/S3
FC5A
‐
D12K1E/S1E
—
—
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
DATA
First
device
address
to
store
read
data
—
X
X
X
X
X
—
—
STATUS
Operating
status
code
— — — — — —
X
—
—
SLOT
Intelligent
module
slot
number
— — — — — — —
1
‐
7
—
ADDRESS
First
address
in
intelligent
module
to
read
data
from
— — — — — — —
0
‐
127
—
BYTE
Bytes
of
data
to
read
— — — — — — —
1
‐
127
—
W
(word)
X
I
(integer)
X
D
(double
word)
—
L
(long)
—
F
(float)
—
When
the
CPU
module
stops,
data
is
read
from
the
area
starting
at
ADDRESS
in
the
intelligent
module
designated
by
SLOT
and
stored
to
the
device
desig
‐
nated
by
DATA.
BYTE
designates
the
quantity
of
data
to
read.
STATUS
stores
the
operating
status
code.
DATA
*****
SLOT
*
STATUS
*****
BYTE
***
ADDRESS
***
STPA(*)
READ
Start
input
is
not
needed
for
this
instruction.
When
a
bit
device
such
as
I
(input),
Q
(output),
M
(internal
relay),
or
R
(shift
register)
is
designated
as
DATA,
16
points
are
used.
When
a
word
device
such
as
T
(timer),
C
(counter),
or
D
(data
register)
is
designated
as
DATA,
1
point
is
used.
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...