![IDEC MICROSmart FC5A Series Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/idec/microsmart-fc5a-series/microsmart-fc5a-series_user-manual_617369103.webp)
8:
D
ATA
C
ONVERSION
I
NSTRUCTIONS
FC5A
MicroSmart
User’s
Manual FC9Y
‐
B1273
8
‐
15
ENCO
(Encode)
Applicable
CPU
Modules
Valid
Devices
For
the
valid
device
address
range,
see
pages
and
(
Basic
Vol.).
Internal
relays
M0
through
M2557
can
be
designated
as
D1.
Special
internal
relays
cannot
be
designated
as
D1.
Valid
values
for
Bits
to
designate
the
quantity
of
bits
searched
are
1
through
256.
Make
sure
that
the
search
area
designated
by
S1
plus
Bits
is
within
the
valid
value
range.
If
the
source
data
is
out
of
the
valid
range,
a
user
program
execution
error
will
result,
turning
on
special
internal
relay
M8004
and
the
ERR
LED
on
the
CPU
module.
Since
the
ENCO
instruction
is
executed
in
each
scan
while
input
is
on,
a
pulse
input
from
a
SOTU
or
SOTD
instruction
should
be
used
as
required.
Examples:
ENCO
FC5A
‐
C10R2/C/D
FC5A
‐
C16R2/C/D
FC5A
‐
C24R2/C/D
FC5A
‐
D16RK1/RS1
FC5A
‐
D32K3/S3
FC5A
‐
D12K1E/S1E
X
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1
(Source
1)
First
bit
to
start
search
X
X
X
X
— —
X
—
—
D1
(Destination
1)
Destination
to
store
search
results
—
X
X
— —
X
—
—
Bits
Quantity
of
bits
searched
— — — — — — —
1
‐
256
—
When
input
is
on,
a
bit
which
is
on
is
sought.
The
search
begins
at
S1
until
the
first
point
which
is
set
(on)
is
located.
The
quantity
of
points
from
S1
to
the
first
set
point
(offset)
is
stored
to
the
destination
designated
by
device
D1.
If
no
point
is
on
in
the
searched
area,
65535
is
stored
to
D1.
ENCO
Bits
S1
*****
D1
*****
D1
D100
S1
M4
I0
ENCO
64
M17
M0
M37
M20
M57
M40
M77
M60
M97
M80
M117
M100
When
input
I0
is
on,
a
bit
which
is
on
is
sought
in
64
bits
starting
at
internal
relay
M4
designated
by
device
S1.
Since
internal
relay
M30
is
the
first
point
that
is
on,
the
offset
from
the
first
search
point
is
20,
and
20
is
stored
to
data
register
D100
designated
by
device
D1.
ON
Searched
area
20
D100
D1
D100
S1
D10
I1
ENCO
64
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
D10
D11
D12
D13
D14
D15
When
input
I1
is
on,
a
bit
which
is
on
is
sought
in
64
bits
starting
at
bit
0
of
data
register
D10
designated
by
device
S1.
Since
bit
8
of
data
register
D11
is
the
first
point
that
is
on,
the
offset
from
the
first
search
point
is
24,
and
24
is
stored
to
data
register
D100
designated
by
device
D1.
ON
Searched
area
24
D100
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...