3 Project Settings Dialog Box
4-30
WindO/I-NV4 User’s Manual
●
System Area
Overview
The area of predetermined device addresses to control the screen and communicate error information and time
information between the MICRO/I and the external device is called the System Area.
The System Area on the MICRO/I is as follows.
To use System Area 1 and 2, select the
Use System Area
check box on the
Project Settings
dialog box. To use
System Area 3 and 4, select the
Use System Area 3, 4
check box.
Specify the word device to use as the System Area in
Device Address
to allocate the System Area starting at the
configured device address.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
Example: When
Device Address
is configured as LDR100
System Area 1
This area configures the MICRO/I display, beep, and clearing bits.
System Area
Number of word addresses
User Access
System Area 1
2
Read and write
System Area 2
2
Write
System Area 3
4
Read
System Area 4
4
Write
LDR100
LDR101
LDR102
LDR103
LDR104
LDR105
LDR106
LDR107
LDR108
LDR109
LDR110
LDR111
System Area 1
(The address number of Top Device Address)
+1
+2
+3
+4
+5
+6
+7
+8
+9
+10
+11
System Area 2
System Area 3
System Area 4
Address
number
Bit
Function
Description
+0
0 to 15
Display screen number
This bit stores the number of the screen being displayed. Write a value to
this bit to change the screen to that number. Immediately after the power
is turned on, the value configured by
Default Screen
in the
Project
Settings
dialog box is stored here.
If the screen number does not exist in the project data, an error message
(No screen data) is displayed. However, when 0 is written to this bit, the
screen is not switched and no error message is displayed.
+1
0
Backlight
This bit stores the illumination state of the backlight. Write a value to this
bit to change the state.
0:
Off
Turns the backlight off.
1:
On
Turns the backlight on.
1
Flash display (1 sec. cycle)
This bit stores the screen flash state (1 sec. cycle). Write a value to this
bit to change the state. This bit is 0 immediately after the power is turned
on.
0:
Do not flash
Stop flashing the screen and turn it on.
1:
Flash
Flashes the screen in one second intervals.
When the Flash display (1 sec. cycle) (address 1, bit 1) and
the Flash display (0.5 sec. cycle) (address 1, bit 2) are both
1, the screen flashes at one second intervals.
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...