Functions
HR9Z-B2202 8/2020
63
Application Function 4
This application function requires the start function selector to be set to positions 1 or 5, automatic
start without startup test. Refer to Start Functions
) for details.
Synchronization:
Wiring of the inputs for two-hand control devices
Characteristic
Value/Description
Typical applications
Monitoring of two-hand control devices,
type III C as per ISO 13851
Type of outputs of sensor/device providing the input signal
for application function
Normally open, normally closed and/or changeover
outputs
S## terminals to be connected
S11-S12 and S11-S13, S21-S22 and S21-S23
Dynamization
Yes
Signal interlock monitoring
Between the pair of terminals S12-S13 and the pair of
terminals S22-S23
Synchronized terminals
Synchronization time
S12-S13 synchronized with S22-S23
S12-S13 and S22-S23 have to be activated within 0.5 s.
Содержание HR6S-S
Страница 1: ...http www idec com HR6S S Safety Module Original instructions HR9Z B2202 ...
Страница 8: ...8 HR9Z B2202 8 2020 ...
Страница 14: ...14 HR9Z B2202 8 2020 ...
Страница 20: ...Introduction 20 HR9Z B2202 8 2020 ...
Страница 56: ...Installation 56 HR9Z B2202 8 2020 ...
Страница 92: ...Accessories Service Maintenance and Disposal 92 HR9Z B2202 8 2020 ...