Functions
HR9Z-B2200 8/2020
59
Application Function 1
Characteristic
Value/Description
Typical applications
Monitoring of Emergency Stop circuits as per
ISO 13850 and IEC 60204-1, stop category 0
Monitoring of guards as per ISO 14119/14120
with electrical switches
Type of outputs of sensor/device providing the input signal
for application function
Normally open, normally closed and/or changeover
outputs
S## terminals to be connected
S11-S12 and S21-S22 for sensor/device A
S11-S13 and S21-S23 for sensor/device B
S31-S32 and S41-S42 for sensor/device C
S31-S33 and S41-S43 for sensor/device D
S51-S52 and S61-S62 for sensor/device E
S51-S53 and S61-S63 for sensor/device F
If less than 6 safety-related inputs are used, the unused
terminals must be bridged as if a sensor/device is
connected (example: sensor/device F not connected: S51
and S53 / S61 and S63 bridged).
Do not configure a start function with startup test if less
than 6 safety-related inputs are used.
Dynamization
Yes
Signal interlock monitoring
Between terminals S12 and S22
Between terminals S13 and S23
Between terminals S32 and S42
Between terminals S33 and S43
Between terminals S52 and S62
Between terminals S53 and S63
Synchronization of safety-related inputs
No
Содержание HR6S-DN
Страница 1: ...http www idec com HR6S DN Safety Module Original instructions HR9Z B2200...
Страница 8: ...8 HR9Z B2200 8 2020...
Страница 14: ...14 HR9Z B2200 8 2020...
Страница 20: ...Introduction 20 HR9Z B2200 8 2020...
Страница 56: ...Installation 56 HR9Z B2200 8 2020...
Страница 60: ...Functions 60 HR9Z B2200 8 2020 Wiring of the inputs for Emergency Stop Wiring of the inputs for guards...
Страница 64: ...Functions 64 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Страница 66: ...Functions 66 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Страница 69: ...Functions HR9Z B2200 8 2020 69 Wiring of the inputs for sensors devices with two PNP outputs...
Страница 72: ...Functions 72 HR9Z B2200 8 2020 Wiring of the inputs for sensors devices with OSSD outputs...
Страница 98: ...Accessories Service Maintenance and Disposal 98 HR9Z B2200 8 2020...