IDEAL VoltAware NCV Скачать руководство пользователя страница 1

#61-025

VoltAware™ Non-Contact Voltage (NCV)Tester

Instruction Sheet

IMPORTANT SAFETY INFORMATION

Read

 and 

understand

 all of the instructions and safety information in these operating instructions before using this tester.

 

WARNINGS

To avoid possible electric shock, personal injury or death follow these guidelines:

•  Do not use if green light is not illuminating on tester.

•  Do not use if tester appears damaged or is not operating properly.

•  Do not use tester for more than the rated voltage on the tester.

•  Do not use without the tester fully assembled.

•  This tester will not detect the presence of DC voltage.

•  For indoor use only. Do not use in damp conditions.

•  This tester will not detect voltages at a distance, such as through walls, metal conduit, or shielded wire.

•  Voltage detection maybe affected by outlet design, insulation thickness/type.

•  Do not assume that no voltage indication means the circuit is de-energized.

•  Voltages below 40VAC will not be detected by the 61-025 but are still shock hazards that can result in injury or death.  

•  Use the 3 Point Safety Method. (1) Verify tester operation by measuring a known voltage. (2) Apply tester to circuit under test. (3) Return to the known 

  live voltage again to ensure proper operation.

•  Ensure all fingers are behind finger guard when testing for voltage.

•  If this tester is used in a manner not specified by IDEAL, protection provided by the product may be impaired.

•  Comply with local and national safety requirements, including the use of appropriate personal protective equipment.

Features:

The VoltAware™ NCVtester is useful for identifying hot conductors, finding breaks in wires and detecting the presence of AC voltage at outlets, switches, 

electrical panels, wires and cables.

•  61-025 model indicates presence of voltage from 40-1000VAC

•  Visual indication of voltage 

•  Selectable Audible indication of voltage

•  Auto shut-off to conserve battery life*

•  Low Battery Indicator

•  Sleek, compact design

Operation:

•  Twist the tester body to the On position.

•  Verify the green light is on.

•  Verify tester operation on a known voltage source.

•  Place the tip of the tester near an AC voltage source to obtain a voltage indication.

•  Voltage presence is indicated by a red, flashing light.

•  If no voltage is detected for a period of 15 minutes, the tester will flash green three times then shut off automatically.* 

  Twist the tester body to the Off position, then back to On to reactivate.

Selectable On/Off for Audible Beeper:

•  The tester defaults to the audible ON mode.

•  To turn the audible Off, depress the dark gray button.

•  To turn the audible back On, depress the button again.

Note: Withdraw tester from voltage source before pressing the button. Audible mode can only be changed while 

the green indicator is lit.

Low Battery Indicator:

•  The tester indicates the low battery condition by turning off the green light. The tester will cease to function.

Battery Replacement:

•  With the tester in the middle position, pull apart the two case halves. 

•  Replace with 2 AAA (LR03) batteries.

•  Reverse process to re-assemble tester.

Maintenance:

Clean with a damp cloth and mild detergent. Ensure completely dry before use. If the tester acts erratically, or 

the green light is not on, change the batteries.

Service and Replacement Parts:

There are no user-serviceable parts. To inquire about service information, contact IDEAL INDUSTRIES, INC. at 

800-435-0705, or visit our website at www.idealind.com.

Specifications

:

Voltage Range:

40-1000VAC (61-025)

Frequency Range:

50-500 Hz

Operating Environment: 

32 to 122°F (0 to 51°C) at <95% R.H.

Storage Temp.:

-4 to 140°F (-20 to 60°C) at <95% R.H.

Battery: 

(2) 1.5V AAA batteries (IEC LR03)

Altitude:

9843 ft. (3000m)

Dimensions:

6.0” (L) x 0.75” (D) [152mm (L) x 19mm (D)]

Weight:

1.6 oz. (46g)

Safety

Complies with UL-61010, EN61010, Cat IV-1000V

   

         Equipment protected by double insulation.

Instrument complies with insulation overvoltage category IV. Cat IV equipment is designed to protect against transients from primary supply level. 

Pollution degree 2 in accordance with IEC-664. Indoor use.
*Auto shut-off feature only available on testers manufactured from 2012.

 

OFF

ON

#61-025

Cat IV 40-1000VAC

OFF

ON

#61-025

40-1000VAC

N12966

Содержание VoltAware NCV

Страница 1: ...er body to the On position Verify the green light is on Verify tester operation on a known voltage source Place the tip of the tester near an AC voltage source to obtain a voltage indication Voltage presence is indicated by a red flashing light If no voltage is detected for a period of 15 minutes the tester will flash green three times then shut off automatically Twist the tester body to the Off p...

Страница 2: ...dido On Verifique que la luz verde esté encendida Verifique la operación del instrumento con una fuente conocida de voltaje Coloque la punta del instrumento cerca de una fuente de voltaje de CA para obtener una indicación de voltaje La presencia de voltaje se indica mediante una luz roja destellante Si no se detecta ningún voltaje por un periodo de 15 minutos el probador parpadeará en verde tres v...

Страница 3: ...les Fonctionnement Mettre le corps de l appareil sur la position de marche en lui imprimant un mouvement rotatif Vérifier que le voyant vert est allumé Contrôler le fonctionnement du testeur sur une source de tension connue Placer le bout du testeur à proximité d une source de tension pour obtenir une indication de tension La présence de tension est indiquée par un témoin rouge clignotant Si aucun...

Страница 4: ...strumento Cualquier garantía implícita originada en la venta de un producto IDEAL incluidas pero sin limitarse a ellas las garantías implícitas de comerciabilidad y adecuación para un propósito particular se limitan a lo indicado anteriormente El fabricante no será responsable por la pérdida del uso del instrumento u otros daños y perjuicios incidentales o consecuentes gastos o pérdidas económicas...