PRESET PROGRAM TIMES AND TEMPERATURES
The programmer comes with preset Central Heating and Hot Water times and temperatures.
These can be amended using the appropriate procedures. The times can be deleted if they are not required (refer to Frame 8).
Central Heating Periods:
Hot Water Periods:
MON-FRI
MON-SUN
Period 1 ON
06:30
Period 1 ON
06:30
Period 1 OFF
08:30
Period 1 OFF
00:00
Period 2 ON
17:00
Period 2 ON
— : —
Period 2 OFF
22:30
Period 2 OFF
— : —
Period 3 ON
— : —
Period 3 ON
— : —
Period 3 OFF
— : —
Period 3 OFF
— : —
SAT-SUN
Period 1 ON
07:30
Period 1 OFF
10:00
Period 2 ON
12:00
Period 2 OFF
14:00
Period 3 ON
17:00
Period 3 OFF
22:30
Radiator Temperature
82
o
C
Hot Water Temperature:
60
o
C
7
FAULT FINDING
If the display shows a ‘spanner’ symbol, and the time or temperature indication is replaced by a 2-symbol Fault Code, then the
boiler is being prevented from running because of adverse conditions.
Those Codes beginning with ‘H’ are temporary and will reset when the fault condition has (been) cleared.
Those Codes beginning with ‘L’ are ‘permanent’, causing a ‘Lockout’ situation.
When one of these faults has been cleared, the boiler should be reset by pressing the ‘Select’ button for greater than 3
seconds.
The Select button is the equivalent of the small Reset button on boilers without programmers.
Further details of the Lockout Codes are in the main boiler instruction book, Fault Finding section.