background image

users guide

ESPRIT 2

Your Ideal users guide

When replacing any part on this appliance use only spare parts that you can be assured 
conform to the safety and performance specification that we require. Do not use 
reconditioned or copy parts that have not been clearly authorised by Ideal.

24, 30, 35

May 2010     UIN 206104 A01

206104-1.pmd

26/05/2010, 16:01

1

Содержание ESPRIT 2 24

Страница 1: ...any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been cl...

Страница 2: ...d combustion A 7 day programmer is built into the boiler capable of 3 timed periods per day Due to the high efficiency of the boiler condensate is produced from the flue gases and this is drained to a...

Страница 3: ...n the heat exchanger does not drop below 4o C If external frost protection is required a kit can be purchased to support an external frost thermostat Boiler overheat thermostat This thermostat will sh...

Страница 4: ...hey have contact your installer Boiler is not working for central heating or hot water but attempts to fire by going through 3 ignition attempts Display shows L F flashing Press select reset button C...

Страница 5: ...MT BST ADJUSTMENT The clock can be easily adjusted between GMT and BST by pressing the UP button for 3 seconds NOTE The time is pre set before leaving the factory If on receipt of the boiler the time...

Страница 6: ...flashing together with the radiator symbol The Radiator symbol is flashing together with o C The right hand Timed is flashing together with the Tap symbol The Tap symbol is flashing together with o C...

Страница 7: ...becomes steady and the 12 24 hr symbol flashes The hours digits flash The hours digits become steady and the minutes digits flash The am or pm symbol flashes in 12 hr mode only The clock now displays...

Страница 8: ...u have selected period 1 on the day s shown ON flashes and a time is showing The hours figure flashes The minutes figure flashes 12 hr mode only The am or pm symbol flashes Use Up and Down Buttons to...

Страница 9: ...and DOWN buttons The Tap symbol is steady The temperature figure flashes Use Up and Down buttons to set value Hot water delivery temperature can be set from 40 to 65 o C Change accepted Display revert...

Страница 10: ...Monday is shown Monday s first OFF time is shown etc The last OFF time for Sunday is shown Return to Monday S P P P S Press PROG button briefly Press PROG button and hold until o C is flashing togeth...

Страница 11: ...Period 3 ON 17 00 Period 3 OFF 22 30 Radiator Temperature 82 o C Hot Water Temperature 60 o C 7 FAULT FINDING If the display shows a spanner symbol and the time or temperature indication is replaced...

Страница 12: ...ay and backlight is OFF DISPLAY SHOWS time day and backlight is ON The left hand Timed is flashing together with the Radiator symbol and the word PROG is showing The left hand Timed is flashing togeth...

Страница 13: ...ols relate to the times being programmed 1 2 and 3 are the daily periods ON and OFF are the functions DEL is used to clear a programmed period PROG is shown during program amendment ON OFF TIMED ADVAN...