IDEAL 61-521 Скачать руководство пользователя страница 1

3-Phase Tester & 
Motor Rotation Tester 

#61-521

Содержание 61-521

Страница 1: ...3 Phase Tester Motor Rotation Tester 61 521...

Страница 2: ...L 2 OPEN PHASE INDICATOR 3 PHASE ROTATION INDICATOR 4 MOTOR TESTER POWER SWITCH 5 MOTOR TESTER POWER INDICATOR 6 MOTOR ROTATION INDICATOR 7 MOTOR ROTATION INPUT TERMINAL 2 3 PHASE TESTER MOTOR ROTATIO...

Страница 3: ...Fig 2 Fig 1 61 521...

Страница 4: ...rding to IEC Publication 348 Safety Requirements for Electronic Measuring Apparatus IEC 1010 En61010 and other safety standards Follow all warnings to ensure safe operation 1 Introduction 1 CAUTION RE...

Страница 5: ...mental conditions 1 Indoor use 2 Installation Category lll 3 Pollution Degree 2 4 Altitude up to 2000 Meter 5 Relative Humidity 80 Max o 6 Ambient Temperature 0 40 C Observe the International Electric...

Страница 6: ...rotation indication This model is ideal for installing conveyor lines pump systems and interconnected drivers Identifies 3 phase sequence and open phase check Battery operated Meets IEC 1010 EN61010 s...

Страница 7: ...are on If so there is no open phase When any of the three lamps is not on there is open phase 4 Check the rotating direction of the rotation indicator 4 Measuring Methods 4 Open phase on terminal wher...

Страница 8: ...input terminals by L1 L2 L3 and press the power button Fig1 The power indicator green lamp is lit If the clockwise or counter clockwise red indicator is lit before rotating the motor shaft it means v...

Страница 9: ...r is lit it means there is a 3 phase motor connection to the power supply by L1 L2 L3 The 3 phase motor should be rotated clockwise 4 If you require the motor to rotate counter clockwise you should ch...

Страница 10: ...ower Consumption Consumption current approx 14mA of motor rotation field of tester AC power consumption approx 7mA per phase rotation field of indicator Installation Category IEC 1010 600V Cat III Dim...

Страница 11: ...ment 1 It is necessary to replace fuse when lamp indicator R or T show no connection and change R S T is the same 2 Use a screwdriver to unscrew the screws on the back then open the case Fig 2 remove...

Страница 12: ...owing the purchase of the tester IDEAL INDUSTRIES INC will at its option replace or repair the defective unit subject to verification of the defect or malfunction Warranty limited solely to repair or...