background image

15

9. (CONT’D)  DISPLAy FUNCTIONS - FAULT MESSAGES

cont’d . . . . . . .

BOILER DISPLAY MESSAGE

DESCRIPTION

ACTION

Boiler Type Card Fault

Contact Installer

BCC Activation Fault

Restart the appliance - if the boiler fails to operate then please 

contact Ideal (if under warranty) or alternatively a Gas Safe 

Registered Engineer if outside of the warranty period.  In IE 

contact a Registered Gas Installer (RGII).

Low Water Pressure

1  Fill System to 1.0 Bar

2  Bleed Radiators

3  Contact Installer

Low Water Pressure

Check system pressure is between 1 & 1.5bar on the pressure 

gauge.  If the fails to operate then please contact Ideal (if under 

warranty) or alternatively a Gas Safe Registered Engineer if 

outside of the warranty period.  In IE contact a Registered Gas 

Installer (RGII).
Check system pressure is between 1 & 1.5bar on the pressure 

gauge.  Restart the appliance.  If the boiler fails to operate then 

please contact Ideal (if under warranty) or alternatively a Gas 

Safe Registered Engineer if outside of the warranty period.  In 

IE contact a Registered Gas Installer (RGII).

PCB Replaced

Restart Boiler

BCC Fault

Restart the appliance - if the boiler fails to operate then please 

contact Ideal (if under warranty) or alternatively a Gas Safe 

Registered Engineer if outside of the warranty period.  In IE 

contact a Registered Gas Installer (RGII).

Overheat Lockout

1  Fill System to 1.0 Bar

2  Bleed Radiators

3  Check Radiator Valves Open

4  Restart Boiler

5  Contact Installer

Flow Temperature Overheat

or No Water Flow

Содержание Logic+ Combi 24

Страница 1: ... Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com where you can download the relevant information in PDF format For alternative languages in our User Guides please visit our website www idealboilers com April 2015 UIN 212140 A01 ...

Страница 2: ...Safety 3 Electricity Supply 3 Important Notes 3 2 Boiler Operation 4 Controls Diagram 4 To Start the Boiler 4 Operation Modes 5 Preheat Domestic Hot Water 5 Control of Water Temperature 5 Efficient Heating System Operation 6 Weather Compensation 6 Boiler Frost Protection 6 Boiler Restart 6 Mains Power Off 6 3 System Water Pressure 7 4 Condensate Drain 8 5 General Information 9 Boiler Pump 9 Minimu...

Страница 3: ...It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler Electricity Supply This appliance must be earthed Supply 230 V 50 Hz The fusing should be 3A Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate seal If the boiler is installed in a compartment then the compartment m...

Страница 4: ... g programmer and room thermostat are on 7 Set the mode knob D to winter The boiler will commence ignition sequence first supplying heat to preheat the domestic hot water and then to the central heating if required Note In normal operation the boiler status display E will display messages see section 7 Note Boiler frost protection boiler will fire if temperature is below 5ºC During normal operatio...

Страница 5: ...ted condition The average time period between operation is 90 minutes This may vary considerably due to the surrounding ambient temperature of the boiler The boiler will operate whenever there is a demand for domestic hot water If standard hot water delivery is satisfactory turn the knob A to preheat off Control of water temperature Domestic Hot Water The domestic hot water temperature is limited ...

Страница 6: ...desired room temperature for all outside weather conditions Boiler Frost protection The boiler is fitted with frost protection that operates in all modes provided the power supply to the boiler is always turned on If the water in the boiler falls below 5ºC the frost protection will activate and run the boiler to avoid freezing The process does not guarantee that all other parts of the system will ...

Страница 7: ...B A Filling Position Starting Position Cap Filling Loop Handle Blue Domestic Hot Water DHW Inlet Valve Filling Loop B A Plug To Top up the system 1 Ensure both A B handles blue are in closed position as shown below 2 Remove the plug and cap and retain 3 Connect the filling loop to the Domestic Hot Water DHW inlet and tighten Also ensure that the other end of filling loop is hand tight 4 Turn the D...

Страница 8: ...tion point Locate the frozen blockage It is likely that the pipe is frozen at the most exposed point external to the building or where there is some obstruction to flow This could be at the open end of the pipe at a bend or elbow or where there is a dip in the pipe in which condensate can collect The location of the blockage should be identified as closely as possible before taking further action ...

Страница 9: ...oiler has been installed for more than 1 year the following message will appear on screen 12 month Service Interval Request Contact Installer Move the mode knob to the restart position for 3 seconds to clear Escape of Gas Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay Telephone 0800 111 999 Ensure that All naked flames are extinguished Do not opera...

Страница 10: ...uld the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit or for any pre arranged visit where access is not gained by the engineer For any queries pleAse ring the ideal consumer helpline 01482 498660 NOTE BOILER Restart PROCEDURE To restart boiler turn mode knob to restart position and immediately turn knob back to required setting The boiler ...

Страница 11: ... mains power is turned on and ensure mode knob D is in the winter position See boiler Display Functions section Does the boiler have a display showing on the front control panel See boiler Display Functions section If Boiler off is displayed then contact Ideal Customer Services Helpline if your appliance is under warranty or a Gas Safe Registered Engineer in IE a Registered Gas Installer RGII if o...

Страница 12: ...efficiency Pre heat operation Domestic hot water set at 59ºC or 50ºC or less Pre heat setting Central heating Temperature 59ºC Temperature 50ºC High efficiency Super efficiency Boiler frost protection Boiler running freeze protection cycle Temperature 5ºC Pump overrun Normal boiler operaton Going to Standby Going to Standby Fan post purge Normal boiler operation Super efficiency Service required 1...

Страница 13: ...ator temperature set to 80ºC Mode knob moved to off position Central heating off Hot water off Mode knob moved to summer position Summer setting Boiler off Central heating off Hot water on Mode knob moved to winter position Winter setting Central heating on Mode knob moved to restart position Restart Hot water on 8 DISPLAY FUNCTIONS SETTINGS CHANGED Note The temperatures shown below are for illust...

Страница 14: ...ontact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Lockout 6 Restart Boiler Contact Installer False Flame Lockout Restart the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period...

Страница 15: ... a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Check system pressure is between 1 1 5bar on the pressure gauge Restart the appliance If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII...

Страница 16: ...pliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Flow Thermistor Fault Contact Installer Flow Thermistor Restart the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Register...

Страница 17: ...17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...pon Hull HU5 4JN Tel 01482 492251 Fax 01482 448858 Registration No London 322 137 Ideal Boilers Ltd pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice ...