ClearMark™
Installation, Operation & User Manual
–
Page 69
V 1.S.10 January 2021
V-1.S.1
Shows the status of the BCD inputs
and the current BCD code.
Shows the status of the Encoder’s
inputs and the number of validated
pulses of each encoder’s channel
for
last 15 seconds.
Output status. Shows in red if the
output is active.
Reset all the values.
Note: LEDs are shown in red if the input is active.
Input Setup:
This menu lets you configure the behaviour of the inputs:
-
Edge / State:
o
Edge: signal activation will not be processed until a change of its state is
detected. If inverted is checked, the signal will be processed when a falling edge
is detected.
o
State: signal activation will be processed if the level is active. If inverted is
checked the signal will be processed when a zero-volt value is detected.
-
Inverted: If checked it inverts the logic of the signal.
-
Filter [ms]: Time that the signal value must be maintained in order to process it.
NOTE:
If there is a problem with multiple trigger detection caused by light reflections, it will
be necessary to increase the photocell’s filter to avoid these reflections. Keep in mind that
photocells’ filters add a delay to the print cycle.