ICT Sine Wave ICT1500-12W Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500W Sine Wave Series 

Inverter 

INSTRUCTION MANUAL 

855-151-000 

 

 

Innovative Circuit 

Technology Ltd. 

 

Models: 

ICT1500-12SW 

ICT1500A-12SW 

ICT1500-24SW 

ICT1500A-24SW 

ICT1500-48SW 

ICT1500A-48SW 

All manuals and user guides at all-guides.com

all-guides.com

Содержание Sine Wave ICT1500-12W

Страница 1: ...erter INSTRUCTION MANUAL 855 151 000 Innovative Circuit Technology Ltd Models ICT1500 12SW ICT1500A 12SW ICT1500 24SW ICT1500A 24SW ICT1500 48SW ICT1500A 48SW All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...actical Ensure battery voltage matches the rating of the model of inverter in use Carefully observe wiring polarity when making input connections Securely tighten all connections Install the wiring box and cover and use appropriate wiring strain relief devices on all wires The ac NEUTRAL line may be internally bonded to the chassis if ground bonding screw is installed Ensure chassis is connected t...

Страница 3: ... IP WEB BASED UTILITY OPTION 11 Status and Control 12 Device Setup 13 Network setup 14 E mail Setup 17 User Setup 18 Maintenance 20 MOBILE WEB APP 21 PASSWORD and IP ADDRESS RESET 21 ROUTER CONFIGURATION 22 TEXT MESSAGE ALARM NOTIFICATIONS 24 TROUBLESHOOTING 24 PRODUCT SPECIFICATIONS 26 LIMITED WARRANTY 28 All manuals and user guides at all guides com ...

Страница 4: ...life Model Numbers and Options factory installed 115Vac 60Hz Models 230Vac 50Hz Models 1 Battery V Description ICT1500 12SW ICT1500 24SW ICT1500 48SW ICT1500A 12SW ICT1500A 24SW ICT1500A 48SW 12 24 48 1500W True Sine Wave inverter ICT1500 12SWT ICT1500 24SWT ICT1500 48SWT ICT1500A 12SWT ICT1500A 24SWT ICT1500A 48SWT 12 24 48 1500W inverter with AC transfer switch option ICT1500 12SWC ICT1500 24SWC...

Страница 5: ...nings to be used for the installation as required The inverter must be installed in a restricted access environment such as an enclosed equipment rack if the back panel wiring junction box is not used Figure 1 Wiring Junction Box Installation Mount the inverter using the wall mount bracket included or the optional 19 inch rack mount tray ICT RMK4 using the 4 mounting screws on the bottom of the in...

Страница 6: ...ations Connect the chassis ground stud on the back panel to a reliable earth ground point Ensure the inverter switch is in the off position then connect the dc input wiring from a suitable deep cycle lead acid battery to the inverter using appropriately rated wire size see DC Wire Sizing Guide and an in line over current protection device disconnect switch or breaker with disconnect switch in off ...

Страница 7: ...ices may be directly plugged in to the AC outlets located on the inverter front panel On units with the Transfer Relay option T connect the external AC power source grid power or AC generator to the AC IN wire clamp connector on the back panel of the inverter using wire rated for at least 15A 14 12AWG with the AC power source switched off Distance from Inverter to Battery 12V input 100Ah min batte...

Страница 8: ...tions to the inverter are correct and tight then tighten the wire strain relief clamps in the wiring junction box if used and install the wiring box cover Set the external battery disconnect switch or breaker to on OPERATION With the unit mounted wired and powered as described in the INSTALLATION section turn the front panel power switch to the ON position and check that the green AC indicator on ...

Страница 9: ...limit and is powering the output Enabled ON DC Undervoltage Warning Triggers when Input Voltage drops below 11 0 22 0 44 0VDC for 1 s Clears when input is above 11 2 22 4 44 8V for 1s Enabled ON Remote Shutdown Triggers when Remote Shutdown is activated over optional Ethernet or remote panel switch OFF BLINK OFF System Fault Indicates internal circuit fault Clears when all fault conditions are cle...

Страница 10: ...ransfer switch ensures that your load is primarily powered from the AC grid or generator when available and is quickly transferred to the battery powered inverter output should the AC power source fail Transfer time is typically less than 1 ac cycle and the voltage transfer thresholds may be adjusted using the back panel DIP switch settings shown in Table 1 The output will be supplied by the inver...

Страница 11: ...rter via the on board graphical web interface using any standard web browser such Microsoft Explorer Google Chrome or Mozilla Firefox To connect with your networked inverter do the following Start your browser Enter the IP address of the inverter in the address field of your browser as shown If the inverter is connected to a network with a DHCP server it will be assigned an IP address automaticall...

Страница 12: ...es information on the input battery voltage the inverter output voltage and power whether the AC output is provided by the inverter or an external AC source units with the optional AC transfer relay only and alarm status for the inverter The inverter output may be enabled or disabled by clicking the on screen On or Off push button Note that disabling the inverter output on units with the transfer ...

Страница 13: ...riodically ping up to two remote IP addresses to verify the network connection status If there is no response from either address the unit will cycle the inverter output power This feature is useful for re booting a modem or other network device that is powered by the inverter to help recover the network IP connection when one of these devices has crashed The inverter output will be held in the of...

Страница 14: ...reater than the normal start up time for the network hardware to prevent nuisance power cycle events at system start up Reset Delay Enter the time 10 to 240 seconds that the inverter will wait before re enabling its output after a watchdog timeout This delay must be long enough for any external networking equipment powered by the inverter to fully shut off to force the equipment to re boot when AC...

Страница 15: ...Primary DNS Specify the IP address of the Primary DNS Server for your network Secondary DNS Specify the IP address of the Secondary DNS Server for your network Web Server CAUTION Changing the web server port numbers may cause loss of communication with the inverter The following ports may be changed within a range of 1 to 65565 if required HTTP Port This port is used for HTTP traffic between the i...

Страница 16: ...tion Base file which can be downloaded from the inverter s Help page The unique inverter MIB file must then be imported into your external SNMP management software Enable SNMP Check this box to enable the SNMP agent Read Community Enter the community string password for read only SNMP access The default read community string is public Trap Community Assign the community string password that will b...

Страница 17: ...he inverter The information required for this is available from your Network Administrator or Internet Service Provider ISP Figure 10 E mail Setup Page E mail SMTP Server Enter the name or the IP address of your SMTP server used for sending outgoing e mail e g smtp gmail com SMTP Port Enter the port used by your SMTP server Normally 25 SMTP Server requires SSL Check this box if your SMTP server re...

Страница 18: ...mail Notifications Select these options to receive an e mail when one or more of these events occurs An inverter failure occurs Check this box to receive an e mail notification when the inverter has an internal fault Inverter Communications reset Check this box to receive an e mail notification when the inverter communications processor resets normally due to either unit start up or remote reset T...

Страница 19: ...o Edit Choose which of the two user accounts to edit Administrator user name admin This account has full access to the inverter settings Standard User user name user This account has read only access to the inverter and cannot enable or disable the outputs or change any of the inverter settings New Password Use these fields to change the password of the selected user New Password Enter the new pas...

Страница 20: ...ntained Restore Factory Default Settings Clicking the Restore button will restore ALL settings to the original factory default values including the user passwords To only restore the network settings and passwords see the Password Reset section Send Test E mail Click the Send Test E mail button to send a test e mail to the listed e mail recipients using the e mail settings on the E mail Setup page...

Страница 21: ...l Private Network VPN connection Mobile Web App A shown above the Mobile Web App provides information on Battery Voltage Inverter Output Voltage Inverter Output Power Output Power Source from battery or external AC source and any alarms Tap on the Inverter Enabled button to toggle the inverter output power on or off PASSWORD and IP ADDRESS RESET Reset the Administrator password the IP address and ...

Страница 22: ...verter is using in the Start and End fields The default HTTP port for the inverter is 80 c Select Both under Protocol TCP and UDP d Enter the local IP address of the inverter e g 192 168 0 180 in the IP address field see step 2 of the TCP IP Web Based Utility section to verify the inverter IP address e Check the Enable box and then click on Save Settings NOTE Many ISP s block access to port 80 so ...

Страница 23: ...may change from time to time without warning depending on your ISP In this case you should obtain a Static IP address from your ISP it will not change which will ensure more predictable access to the inverter from a remote location If a static IP address is not available you can use a Dynamic DNS service such as Dyn www dyn com to provide a stable address for the router 6 To access the inverter ov...

Страница 24: ...s com Telus cellnumber msg telus com Virgin Mobile Can cellnumber vmobile ca TROUBLESHOOTING I am unable to access the web based configuration utility Check that you are using the correct IP address for the inverter by running the IP Address Discovery Utility available on the Tools download section of the ICT Web page http www ictcorporate com resources tools to locate the connected inverter and s...

Страница 25: ...ails from the inverter Verify that the Send E mail checkboxes are ticked for any alarm conditions for which you wish to receive e mail notifications Verify your e mail settings by going to the Maintenance page on the inverter s web utility and clicking on the Send Test E mail button to send a test message to your designated recipient addresses The Send Test E mail page will show an error message i...

Страница 26: ...w 15mW Output Frequency 115Vac models 60Hz 0 2Hz Output Frequency 230Vac models 50Hz 0 2Hz Output Voltage 115Vac models 115Vac 5Vac Output Voltage 230Vac models 230Vac 10Vac Output Sinewave Distortion typical 3 THD Transfer Time Grid to Inverter Option T 1 cycle Ethernet Network Port Option C RJ45 connector 10 100Base T SNMP SNMP v1 v2c supported Alarm Output Form C contact 0 5A 60Vdc max DC Input...

Страница 27: ...or a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communi...

Страница 28: ...e ICT product specifications and capabilities at the time of publication However because of ongoing improvements and updating of ICT products ICT cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes errors or omissions If this ICT product is not in good working order as outlined in the above warranty your sole remedy shall be repair o...