Connection Terminals
The
power
and
control
connector for the PRT-IPIC-POE-C intercom unit.
Connection Terminals
1
2
3
4
5
6
7
+12V
VSS
NC
COM
NO
S-IN
S-OUT
12V 1A/DC
Output Port
Input Port
Output Port Contacts
⦁
NC:
Normally closed (passive mode)/No12V (active mode)
contact
⦁
COM:
Common
contact
⦁
NO:
Normally open (passive mode)/Normally 0V (active mode)
contact
JP1 Jumper
The intercom has two power output options; passive mode and active mode.
⦁
Passive mode
: When the output device current is
more
than 12v/650mA the
external
drive mode is required.
The control output interface is for short circuit output control.
⦁
Active mode
: When the output device current is
less
than 12v/650mA the
internal
drive mode can be used.
The control output interface is 12V DC output.
The default configuration is
passive mode
, as shown in the jumper port configuration above.
By default, only one of the jumper shunts is connected, to ports 2 and 3. To change to
active mode
relocate the
jumper shunts so that ports 1, 2, 3 and 4 are all connected.
PRT-IPIC-POE-C | Vandal Resistant VoIP Intercom with Camera | Installation Manual
10