Страница 3: ...7 Additional Controller Programming 19 Programming the Onboard Reader 19 Programming Controller Inputs 20 Input Duplexing 20 Trouble Inputs 21 Configuring the Cellular Modem Connection 23 Maintaining...
Страница 4: ...Upgrading Application Software and Module Firmware 34 Hardware Configuration 35 Setting the IP Address from a Keypad 35 Temporarily Defaulting the IP Address 36 Defaulting a Controller 38 Disclaimer...
Страница 5: ...Rail Single Door Controller About This Module The Protege WX controller is the central processing unit responsible for the control of security access control and building automation in the Protege WX...
Страница 6: ...network using RS 485 communication NIST Certified AES 128 192 and 256 Bit encryption Factory loaded HTTPS certificate OSDP configurable RS 485 Reader ports 2 2 1 High security monitored inputs 8 8 2 O...
Страница 7: ...og in to the controller for the first time open a web browser and enter the default IP address of 192 168 1 2 with the prefix https e g https 192 168 1 2 If you cannot access the controller with this...
Страница 8: ...website if you do not already have it 2 Open Firefox type about profiles into the URL bar and press Enter 3 Click Create a New Profile to open the wizard 4 Click Next 5 Enter a descriptive profile nam...
Страница 9: ...on service then your license is activated automatically Important The automatic activation process requires an internet connection on the workstation you are using to connect to the controller If this...
Страница 10: ...ect to IP Address This is the IP address that the controller is currently using By default this is set to 192 168 1 2 Subnet Mask Used in conjunction with the IP address a netmask must be configured t...
Страница 11: ...Navigate to the System Settings 6 In the Adaptor Onboard Ethernet tab select the Enable DDNS checkbox 7 Enter the Hostname subdomain duckdns org and DDNS Server duckdns org 8 Leave the DDNS Username b...
Страница 12: ...uthority Installing a self signed certificate recommended for testing only For configuration and version requirements refer to AN 280 HTTPS Connection to the Protege WX Controller available from the I...
Страница 13: ...od is to configure the router to forward all traffic from external port 443 the default HTTPS port to the controller s internal HTTPS port as in the image below Controller IP 192 168 1 2 Router Extern...
Страница 14: ...mapping whenever the external IP address changes Controllers also have an integrated DDNS client which supports several free DDNS providers Third Party Certificate One door controllers currently suppo...
Страница 15: ...se details will be incorporated into your certificate and publicly viewable from the web browser Ensure that the Common Name is the same as the Domain Name which is being used for the controller Some...
Страница 16: ...ctory open the bin folder locate the openssl executable and run it as an administrator This will open the OpenSSL command prompt 2 Export your certificate as a pfx file using the following command rep...
Страница 17: ...SL command prompt 3 To generate your certificate enter the following command req new newkey rsa 2048 x509 sha256 subj C Country code CN Common name days 365 out name crt keyout name key Replace name w...
Страница 18: ...lidation file is required for this method as the connection is not validated by a third party 6 Enter the export password that you created when generating the certificate file 7 Click Save then restar...
Страница 19: ...Input Port 1 Input 3 Bond Sense Port 1 General Purpose Input Input 4 REN Input Port 1 General Purpose Input Input 5 Door Contact Port 2 Door Contact Port 2 Input 6 REX input Port 2 REX Input Port 2 In...
Страница 20: ...plex configuration 1 To enable this feature navigate to System Settings and enter the following command DuplexZones true 2 In addition you will need to manually add the additional input records in Pro...
Страница 21: ...Description Type Group CP001 01 Reserved CP001 02 12V Supply Failure Power Fault General CP001 03 Reserved CP001 04 Real Time Clock Not Set RTC Clock Loss General CP001 05 Service Report Test CP001 0...
Страница 22: ...Group CP001 02 12V Supply Failure Power Fault General CP001 04 Real Time Clock Not Set RTC Clock Loss General CP001 05 Service Report Test CP001 08 Auxiliary Failure Power Fault General CP001 13 Modul...
Страница 23: ...is unique to that network It is important to use the correct APN for the cellular service required Cellular Username The username for the cellular network account Cellular Password The password for th...
Страница 24: ...ts until a valid login is made It is not possible to configure the length of time for the login stand down One door controllers may require additional steps to access the web interface For more inform...
Страница 25: ...ia a router or externally via the internet If the controller is factory defaulted any user created HTTPS certificates are removed and the default certificate is reloaded Custom certificates will need...
Страница 26: ...e DNS server being used by the controller This is required if a DNS name is being used for the connection Programming the IP address subnet mask and default gateway requires knowledge of the network a...
Страница 27: ...ion status and details External Modem Detected Indicates whether the controller is able to communicate with the cellular modem connected to its USB port SIM Detected Indicates whether the controller i...
Страница 28: ...ill communicate over Touch Screen Comms UDP 9460 is disabled by default It can be enabled by adding EnableTLCDCommsUDP true to the Commands field in the controller programming Note Ping is disabled by...
Страница 29: ...ction protocols are not supported This feature is only available in Advanced Mode Configure your Email Server Settings Currently the following email servers are supported Microsoft Exchange Server 201...
Страница 30: ...Even or Odd Parity Parity Location The parity location defines the location of the parity bit in the received data Parity Start Defines where the location of the parity block starts in the received da...
Страница 31: ...options between 2 4 allowed for a user PIN Selecting not set allows more than 4 repetitive digits for example 11111 PIN Expiry Time The frequency at which users will be prompted to reset their PIN at...
Страница 32: ...Only operators with sufficient security permissions will have access to changing passwords for other operators Any operator can change their own password on the Home Page 1 Navigate to System Operato...
Страница 33: ...ensure that they are unique This option splits the username by space period comma hyphen or underscore to ensure that no parts of the username more than two characters exist in the password If this op...
Страница 34: ...is used to update the firmware of any module connected to the controller Select the connected module that requires a firmware update from the dropdown BIN File Click Upload Firmware to browse to the f...
Страница 35: ...ulting the Controller in this document to reset the code Note that this will erase all existing programming as well as setting up the default installer code 3 Once logged in select Menu 4 Install Menu...
Страница 36: ...link between Reader 1 D0 input and Reader 1 L1 output BZ L1 D1 NB READER 1 D0 NA 4 Power up the controller Wait for the status indicator to begin flashing steadily Defaulting the IP Address of a Sing...
Страница 37: ...troller by entering https 192 168 111 222 into the address bar of your web browser and view or change the IP address as required Remember to change the subnet of your PC or laptop to match the subnet...
Страница 38: ...n flashing steadily 5 Remove the wire link before making any changes to the controller s configuration Defaulting a Single Door Controller 1 Remove power to the controller by disconnecting the 12V DC...
Страница 39: ...or must be recreated All other programming is removed After Defaulting a Controller Before making any changes to the controller s configuration or upgrading the firmware remove the wire link used to d...
Страница 40: ...s shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development...
Страница 41: ...aimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to...