background image

THE

POWER

OF

RELIABILITY

INNOVATIVE CIRCUIT TECHNOLOGY LTD.

855-315-004

ICT ISOLATED SERIES 2

INSTRUCTION MANUAL

CONVERTERS

OUTLINE DRAWING

DIMENSIONS IN INCHES 

OUTLINE DRAWING

1.77

9.50

4.10

8.90

3.10

1.77

2.45

9.35

8.75

3.92

4.90

Drawing A

Drawing B 

Input

Voltage

Range

Output

Voltage

Output

Current 

(Cont.)

Output

Current 

(Peak)

Current

Limiting

Line

Regulation

Load

Regulation

Output 

Ripple 

(Max)

Efficiency

(Typical)

ICT1212-12AI2

ICT1212-35AI2

ICT1224-10AI2

11-18 VDC

13.8 VDC

+/- 150 mV

10.0 Amps

12.0 Amps

12.5 Amps

+/- 5%

20mV RMS

88%

Input

Fuse

20 Amp

60 Amp

35 Amp

13.8 VDC

+/- 150 mV

32.0 Amps

35.0 Amps

35.5 Amps

+/- 5%

20mV RMS

90%

11-18 VDC

11-18 VDC

27.6 VDC

+/- 300 mV

8.0 Amps

10.0 Amps

10.5 Amps

+/- 5%

30mV RMS

90%

Model 

Number 

0.5%

    0.5%

0.5%

    0.5%

0.5%

    0.5%

Dimensions 

Drawing A 

Drawing A 

Drawing B 

Operating

Temperature

Range 

   -20°C to +40°C

   -20°C to +40°C

   -20°C to +40°C

0.5%

20-60 VDC

4.0 Amps

5.0 Amps

5.5 Amps

+/- 5%

20-60 VDC

13.8 VDC

+/- 150 mV

10.0 Amps

12.0 Amps

12.5 Amps

+/- 5%

8.0 Amps

10.0 Amps

10.5 Amps

+/- 5%

13.8 VDC

+/- 150 mV

32.0 Amps

35.0 Amps

35.5 Amps

+/- 5%

17.0 Amps

20.0 Amps

20.5 Amps

+/- 5%

20-60 VDC

11-30 VDC

27.6 VDC

+/- 300 mV

20-60 VDC

48.0 VDC

+/- 300 mV

13.8 VDC

+/- 150 mV

90%

90%

35 Amp

15 Amp

20 Amp

20 Amp

40 Amp

ICT103048-5AI2

ICT206012-12AI2

ICT206012-20AI2

ICT206024-10AI2

ICT206012-35AI2

ICT1224-20AI2

30mV RMS

90%

20mV RMS

88%

30mV RMS

20mV RMS

20mV RMS

90%

60 Amp

17.0 Amps

20.0 Amps

20.5 Amps

+/- 5%

30mV RMS

90%

11-18 VDC

27.6 VDC

+/- 300 mV

    0.5%

0.5%

    0.5%

0.5%

    0.5%

0.5%

    0.5%

0.5%

    0.5%

0.5%

    0.5%

Drawing A 

Drawing A 

Drawing A 

Drawing A 

Drawing B 

Drawing B

   -20°C to +40°C

   -20°C to +40°C

   -20°C to +40°C

   -20°C to +40°C

   -20°C to +40°C

   -20°C to +40°C

1. The REMOTE control input requires a voltage between 10VDC and 60VDC referenced to the input ground to enable the output of the converter.  
Converters ship with a jumper connecting the REMOTE input and the input positive terminal, which must be removed before the control feature will function.

SPECIFICATIONS

2. The REMOTE control will disable the converter when the remote terminals connected to the INPUT NEG terminal of the converter. The converter is enabled 
when the REMOTE terminal is left floating.

Remote 

Terminal

Operation

Note 1)

Note 1)

Note 1)

Note 1)

Note 1)

Note 1)

Note 1)

Note 1)

Note 1)

27.6 VDC

+/- 300 mV

18.0 Amps

20.0 Amps

21 Amps

+/- 5%

20-60 VDC

90%

40 Amp

ICT206024-20AI2

30mV RMS

0.5%

    0.5%

Drawing B

   -20°C to +40°C

Note 1)

Отзывы: