background image

OPERATION MODES

LINEAR POTENTIOMETER MODE 100KOHM

POTENTIOMETER WIRING 2AMDI511VPVRDBS - FIGURE N. 2

In order to activate this mode of control/operation just connect a linear potentiometer of 100 Kohm between the D+
and D- inputs and disconnect the remaining inputs.

By default, the dimming curve follows a logarithmic trend proportional to the resistance value set by the
potentiometer.

A resistance value of less than 5 Kohm is interpreted as load off.  
The maximum brightness value is reached by exceeding the value of 95 Kohm.

In case the potentiometer is disconnected, the dimmer sets the output to the saved level (see preset level
change).
The preset value is zero by default.

On the first run in this mode it could be necessary to set the input to a value greater than 50% (55K or higher on D-
D + input) in order to configure the dimmer to the potentiometer mode.

*This setting can be configured through the interface cod. 2AMIN4030000N

ATTENTION IN THIS MODE THE BLUETOOTH CONTROL IS FORBIDDEN

6

IOTLIGHT - User Manual 2AMDI511VPVRDBS

Содержание 2AMDI511VPVRDBS

Страница 1: ...AL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES LINEAR POTENTIOMETER MODE 100KOHM MODE 0 10V 1 10V NOT ISOLATED PASSIVE PUSH MODE DALI MODE BLUETOOTH MODE PUSH PA...

Страница 2: ...h connection Protection against accidental contact with live parts is garantied by the enclosure Power Connector Cross section of conductors 14 30 AWG 0 05 2 08 mmq Interface Connector Cross section o...

Страница 3: ...ll connections must be made with non live devices and carried out by specialized personnel If the control voltage of the PUSH input is higher than the SELV voltage it is necessary to use the OPTIONAL...

Страница 4: ...OUTPUT POWER CONTROL INPUTS CASE DIMENSION mm 2AMDI511VPVRDBS 8 53V DC 12A 1 576W at 48V DC Insulated Push button x1 DALI x1 Linear Potentiometer 100K x1 0 10V Passive x1 1 10V Passive x1 Bluetooth LE...

Страница 5: ...y showed in FIG 1 through the DC IN and terminals In case the power supply polarity is inverted no damage will be caused to the device The LED LED PWR positioned on the circuit board indicates the pre...

Страница 6: ...an 5 Kohm is interpreted as load off The maximum brightness value is reached by exceeding the value of 95 Kohm In case the potentiometer is disconnected the dimmer sets the output to the saved level s...

Страница 7: ...arithmic trend proportional to the control voltage A voltage value of less than 1V is interpreted as load off In case the 0 10V 1 10V signal is disconnected the dimmer sets the output to the saved lev...

Страница 8: ...ded for the input signal The maximum current absorbed by the PUSH interface is about 2mA The dimmer saves the output position in order to restore the set level in case of power failure preset PUSH int...

Страница 9: ...luetooth CONTROL IS FORBIDDEN Below you can find the implemented standard commands DIRECT ARC POWER OFF UP DOWN STEP UP STEP DOWN RECALL MAX LEVEL RECALL MIN LEVEL STEP DOWN AND OFF ON AND STEP UP GO...

Страница 10: ...ERY ACTUAL LEVEL QUERY MAX LEVEL QUERY MIN LEVEL QUERY POWER ON LEVEL QUERY SYSTEM FAILURE LEVEL QUERY FADE TIME FADE RATE QUERY SCENE LEVEL 0 15 QUERY GROUPS 0 7 QUERY GROUPS 8 15 QUERY RANDOM ADDRES...

Страница 11: ...ation and recall of your favourite lighting sceneries The system management from a single simplified user interface THE BLUETOOTH LE CONNECTION DOES NOT REQUIRE PAIRING PROCEDURE IoT Light App feature...

Страница 12: ...product data sheet of the IoT Light application As an alternative you can download the app by clicking on one of two links below Apple https itunes apple com app iot light id1233209834 mt 8 Android h...

Страница 13: ...OFF OFF OFF OFF OFF OFF Linear OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON PWM Configuration A B C D 1 2 3 4 5 6 7 8 9 10 PWM Standard OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF...

Отзывы: