manualshive.com logo in svg
background image

Operating instruction 

Temperature calibrator TP 18 200 E 

List of contents 

Page 

1   Description of the temperature calibrator TP 18 200 E ...................................................................................... 2 
2   Safty instructions ................................................................................................................................................ 2 
3   Operation of the calibrator .................................................................................................................................. 4 
3.1   Adjustment of the handle ................................................................................................................................. 4 
3.2   Operating position............................................................................................................................................ 4 
3.3   Adapter sleeves ............................................................................................................................................... 4 
3.4   Control of temperature sensors ....................................................................................................................... 4 
3.5   Front panel description .................................................................................................................................... 4 
3.6   Switching on of the calibrator .......................................................................................................................... 5 
3.7   Indication of the block temperature and set temperature ................................................................................ 5 
3.8   Adjustment of the block temperature ............................................................................................................... 5 
3.8   Programming of the set point .......................................................................................................................... 6 
4   Cooling down the heating block .......................................................................................................................... 6 
5   Recalibration ....................................................................................................................................................... 6 
6   Error signalling .................................................................................................................................................... 6 
7   Cleaning .............................................................................................................................................................. 6 
8   Disposal .............................................................................................................................................................. 7 
9   Guarantee and repairs ........................................................................................................................................ 7 
10   Technical Data .................................................................................................................................................. 7 

Содержание SIKA TP 18 200 E

Страница 1: ...erating position 4 3 3 Adapter sleeves 4 3 4 Control of temperature sensors 4 3 5 Front panel description 4 3 6 Switching on of the calibrator 5 3 7 Indication of the block temperature and set tempera...

Страница 2: ...o the current state of technology This refers to measuring accuracy function as well as safe operation of the devices To grant safe operation competent and responsible behaviour of the operator is ess...

Страница 3: ...and control device to be used according to EN61010 1 for the altitudes operation until 2000 m The use of the instrument for applications not expressly permitted by the above mentioned rule must adopt...

Страница 4: ...essary to use exactly adapted pockets The right bore is the outer dameter of the device under test 0 5 mm 3 4 Control of temperature sensors For the test of temperature sensors a separate temperature...

Страница 5: ...brass block up from ambient temperature to the adjusted set point value 3 7 Indication of the block temperature and set temperature The red 4 digit 7 segment LED PV shows continuously the temperature...

Страница 6: ...ng block and test piece Before transportation or touching the heating block the block has to be cooled down 5 Recalibration The test instrument series TP18 000 E have been adjusted and checked before...

Страница 7: ...a detailed description of the faults found without any fees or charge for SIKA except in the event of alternative agreements 10 Technical Data Regulation of the heating block with PID regulator Adjust...

Страница 8: ...Fuse 1 6 A T 230VAC 3 15 A T 115VAC Operating temperature 0 50 C Operating humidity 30 95 RH without condensation Storage temperature 10 60 C Compliance 2014 35 EC EN 61010 2014 30 EC EN 61326 1 Dime...

Отзывы: