Auto Sentry®
flex
User Manual
104
Service Unit Screen
Version information may include but is not limited to the following application names:
CAGE.exe. Credit card clearing software.
CoreGatewayServer.exe. Sever application.
Touch.exe.
WashConnect®
touch-screen software.
Deviceint.exe. Device interface software.
Bill Acceptor. Configured bill acceptor for the
WashConnect®
.
Bill Dispenser Diagnostics and Life History
Sensor Health
,
Pot Level
(potentiometer) and
Legend
are displayed for
Fujitsu
™ brand bill
dispensers.
Pot Level
shows the MDS sensor health.
Life History
is displayed for both
Fujitsu
and
De La Rue
™ brand bill dispensers.
Life history
shows
errors and more on the board until it is reset.
Exiting the Service Unit Screen
Once all maintenance has been completed in the main Service Unit Screen or Diagnostics Screen,
tap the
Exit
button.
Figure 75. Exit Button on Service Unit Screen
Reset Alarm
If the alarm deterrent device input is continuous (not momentary) or there is a need to deactivate
the alarm outputs, we will allow the employee to enter the Service Unit Screen by logging in with
the proper credentials and allow them to access the Diagnostics screen. From the Diagnostics
screen, there will be two buttons at the center bottom of the screen labeled Reset Alarm and Dis-
able Alarm. When the outputs are still active, the employee may turn them off by selecting the
Reset Alarm button. If they need to do some maintenance while in the unit they may select the
Disable Alarm button to prevent the alarm from inadvertently going off. When the Disable Alarm
button is selected, the button reappears as Enable Alarm. Selecting the Enable Alarm button reac-
tivates the alarm to be ready to monitor warnings again. If the employee forgets to enable the
alarm, leaving the Service Unit screen will automatically enable the alarm for you.
1
Open the Auto Sentry, and log in to the Service Unit - Diagnostics screen.
Two buttons appear at the center bottom of the screen labeled Reset Alarm and Disable Alarm.
2
When the outputs are still active, the employee may turn them off by selecting the
Reset
Alarm
button.
Содержание Auto Sentry flex
Страница 1: ...User Manual Version 2 0 Auto Sentry flex ...
Страница 14: ...Auto Sentry flex User Manual 14 List of Figures ...
Страница 33: ...Auto Sentry flex User Manual 33 Introduction Figure 16 Moneris Card Reader bottom of unit ...
Страница 34: ...Auto Sentry flex User Manual 34 Introduction Figure 17 Credit Card Reader face ...
Страница 72: ...Auto Sentry flex User Manual 72 Operating Figure 48 Wash Purchase and Extra Service with Club Card 1 2 3 4 ...
Страница 74: ...Auto Sentry flex User Manual 74 Operating Figure 49 Wash Purchase with Club RFID Tag 3 5 1 2 4 ...
Страница 92: ...Auto Sentry flex User Manual 92 Operating ...
Страница 112: ...Auto Sentry flex User Manual 112 Service Unit Screen ...
Страница 114: ...Auto Sentry flex User Manual 114 Marketing with your Auto Sentry Figure 78 Custom Button Enabled for PLU 5 ...
Страница 166: ...Auto Sentry flex User Manual 166 Marketing with your Auto Sentry ...
Страница 168: ...Auto Sentry flex User Manual 168 Reports Figure 123 Shift Detail Report Page 1 ...
Страница 169: ...Auto Sentry flex User Manual 169 Reports Figure 124 Shift Detail Report Page 2 ...
Страница 188: ...Auto Sentry flex User Manual 188 W Wash busy 91 Wash code expired 89 not valid 89 ...
Страница 190: ...Auto Sentry flex User Manual 190 ...