Technical data
—
IVMZ
.2
- 16 -
• Ba_
IVMZ
.2_en • 06a/2021
9 Technical data
The technical data of customised versions may differ from the data in these instructions.
Please observe the information specified on the type plate.
9.1 Characteristics
IVMZ
.2
Type
I
VMZ03
I
VMZ06
I
VMZ08
I
VMZ15
I
VMZ20
I
VMZ25
Measurement device characteristics
Flow range [l/min]
0.1…2
0.25..5
1…20
2.5…50
5…200
12.5…250
Accuracy*
±0.7 % of reading ±0.3 % of range
Repeatability
±1%
Output signal starting
from [l/min]
0.05
0.1
0.25
1
4
5
Max. flow rate [l/min]
2.5
6
25
60
240
300
Response time
< 100 ms
Indication
LED green, flow proportional flashing
Output signal characteristics
Frequency output:
- Pulse rate / K-Factor
[pulses/l]
10 000
4000
1000
400
200
80
- Resolution [ml/pulse]
0.1
0.25
1.0
2.5
5.0
12.5
- Signal shape
Square wave signal • duty cycle 50:50
Push-Pull • NPN open collector • PNP open collector
- Signal current
≤
100 mA
Analogue output 4...20 mA (optional)
Corresponds to flow
rate [l/min]
0...2
0...5
0…20
0…50
0…200
0…250
Max. burden
250 Ω
to GND
Analogue output 0.5...10 V (optional)
Corresponds to flow
rate [l/min]
0...2
0...5
0…20
0…50
0…200
0…250
Electrical characteristics
Supply voltage
12...24 V
DC
(±10 %)**
Power consumption
Max 3.6 W
Electrical protection
measures
short-circuit proof • protected against polarity reversal
Electrical connection
4-pin plug M12x1
Degree of protection
(EN 60529)
IP 65 (only with a connected coupling)
* test conditions: Water 23 °C
** Voltage output 0.5…10 V only available with 16…24 VDC