2 Safety 

WIKA Operating Instruction, Model CPG500 

  7 

14034181.

01 

01

/201

3

 G

B/

D

 

GB

2.2 

Personnel qualification 

WARNING! 
Risk of injury should qualification be insufficient! 

Improper handling can result in considerable injury and damage to equipment. 

The activities described in these operating instructions may only be

 

carried out by 

skilled personnel who have the qualifications described

 

below. 

Skilled personnel 

Skilled personnel are understood to be personnel who, based on their technical training, 
knowledge of measurement and control technology and on their experience and knowledge of 
country-specific regulations, current standards and directives, are capable of carrying out the work 
described and independently recognising potential hazards. 

Special operating conditions require further appropriate knowledge, e.g. of aggressive media. 

2.3 

Special hazards 

WARNING! 

Use the CPG500 digital pressure gauge only with safe gases and liquids per

directive 67/548/EEC.

If it is obvious that safe operation of the instrument is no longer possible, the

instrument must be put out of operation and marked in order to secure it against

inadvertent use.

The measurement signal of the reference (or test sample) can be influenced by

massive electromagnetic irradiation and/or the indication of the signal could be
completely absent.

If the digital pressure gauge CPG500 is used in applications with oil as a pressure

medium, make sure it will not be used with flammable material or gases directly
afterwards since it can lead to dangerous explosions and danger to personnel
and machinery.

Digital pressure gauges should only be fitted or remored when the system is free

from pressure.

Observe the working conditions in accordance with chapter “3. Specifications”.

Always operate the pressure indicator within its overload limits.

Содержание CPG500

Страница 1: ...Digital pressure gauge model CPG500 GB Digitalmanometer Typ CPG500 D Digital pressure gauge model CPG500...

Страница 2: ...2 WIKA Operating Instruction Model CPG500 14034181 01 01 2013 GB D GB Operating instructions model CPG500 Page 1 18 D Betriebsanleitung Typ CPG500 Seite 19 34...

Страница 3: ...mmissioning operation 12 6 1 Commissioning 12 6 1 1 Changing the batteries 12 6 2 Operating the CPG500 digital pressure gauge 13 6 2 1 Turning on ON 13 6 2 2 Turn off OFF 13 6 2 3 Turn on backlight 13...

Страница 4: ...ions for the range of use of the CPG500 digital pressure gauge The operating instructions are part of the instrument and must be kept in the immediate vicinity of the CPG500 digital pressure gauge and...

Страница 5: ...ntially dangerous situation which can result in serious injury or death if not avoided CAUTION indicates a potentially dangerous situation which can result in light injuries or damage to equipment or...

Страница 6: ...y The technical specifications contained in these operating instructions must be observed Improper handling or operation of the CPG500 digital pressure gauge outside of its technical specifications re...

Страница 7: ...nowledge e g of aggressive media 2 3 Special hazards WARNING Use the CPG500 digital pressure gauge only with safe gases and liquids per directive 67 548 EEC If it is obvious that safe operation of the...

Страница 8: ...3 Specifications 8 WIKA Operating Instruction Model CPG500 14034181 01 01 2013 GB D GB 3 Specifications...

Страница 9: ...s 4 3 Functions and keys 4 digit LCD Display with backlight Displays measurement values and menu functions Actual value display Battery status Bargraph with Peak Hold Funktion MIN MAX or FullScale FS...

Страница 10: ...he following settings can be made in the MENU function Auto Power Off on or off Unit selection bar PSI kPa MPa Press the MENU key for 2 seconds to activate the functions menu Press the MENU key again...

Страница 11: ...objects Mechanical vibration mechanical shock putting it down hard Soot vapour dust and corrosive gases Potentially explosive environments flammable atmospheres Store the CPG500 digital pressure gauge...

Страница 12: ...vice is operational as soon as it is turned on 6 1 1 Changing the batteries CAUTION Turn off the device before replacing the batteries Open the battery compartment Insert the new batteries as depicted...

Страница 13: ...the display in sequence The MIN MAX function is used to measure pressure peaks The respective lowest MIN and highest MAX measured values are stored in the MIN MAX memory Values in the MIN MAX memory a...

Страница 14: ...500 is pressure less please contact WIKA 6 2 8 Zero point correction ZERO The zero point can be corrected manually if undesired deviations occur when no system pressure is being applied atmospheric pr...

Страница 15: ...r 2 seconds Depending on the device configuration two different displays are possible Auto Power Off Continuous operations PO On Press Auto Power Off is activated after 5 minutes PO OFF Press The devi...

Страница 16: ...D GB 6 2 12 Filter settings Press for 2 seconds Press Press Press once briefly Filter selection is indicated Filter 0 no damping Filter 3 max damping Confirm filter configuration 6 2 13 Display seria...

Страница 17: ...ressure gauge before returning it in order to protect staff and the environment from exposure to residual media Residual media in dismounted CPG500 digital pressure gauge can result in a risk to perso...

Страница 18: ...ge use the original packaging or a suitable transport package To avoid damage 1 Wrap the CPG500 digital pressure gauge in an antistatic plastic film 2 Place the CPG500 digital pressure gauge along wit...

Страница 19: ...6 Inbetriebnahme Betrieb 28 6 1 Inbetriebnahme 28 6 1 1 Batteriewechsel 28 6 2 Bedienung des CPG500 29 6 2 1 Einschalten ON 29 6 2 2 Ausschalten OFF 29 6 2 3 Beleuchtung einschalten 29 6 2 4 MIN MAX A...

Страница 20: ...des Digitalmanometer CPG500 geltenden rtlichen Unfallverh tungsvorschriften und allgemeinen Sicherheitsbestimmungen einhalten Die Betriebsanleitung ist Produktbestandteil und muss in unmittelbarer N...

Страница 21: ...od oder zu schweren Verletzungen f hren kann wenn sie nicht gemieden wird VORSICHT weist auf eine m glicherweise gef hrliche Situation hin die zu geringf gigen oder leichten Verletzungen bzw Sach und...

Страница 22: ...iert und darf nur dementsprechend verwendet werden Die technischen Spezifikationen in dieser Betriebsanleitung sind einzuhalten Eine unsachgem e Handhabung oder ein Betreiben des Digitalmanometer CPG5...

Страница 23: ...ssen z B ber aggressive Medien 2 3 Besondere Gefahren WARNUNG Das Digitalmanometer CPG500 ausschlie lich mit ungef hrlichen Gasen und Fl ssigkeiten nach Richtlinie 67 548 EWG verwenden Wenn anzunehmen...

Страница 24: ...3 Technische Daten 24 WIKA Betriebsanleitung Typ CPG500 14034181 01 01 2013 GB D D 3 Technische Daten...

Страница 25: ...CD Display mit Hintergrundbeleuchtung Anzeige der Messwerte und Men funktionen Istwertanzeige Batterie Status Bargraph mit Peak Hold Funktion MIN MAX oder FullScale FS Anzeige Beschreibung Bargraph Ze...

Страница 26: ...Einstellungen vorgenommen Automatische Abschaltung ein oder aus Einstellen der Messeinheit bar PSI kPa MPa Durch Dr cken der Taste MENU 2 s wird das Funktionsmen aktiviert Durch erneutes Bet tigen der...

Страница 27: ...enst nden Mechanische Vibration mechanischer Schock hartes Aufstellen Ru Dampf Staub und korrosive Gase Explosionsgef hrdete Umgebung entz ndliche Atmosph ren Das Digitalmanometer CPG500 in der Origin...

Страница 28: ...lten ist das Ger t betriebsbereit 6 1 1 Batteriewechsel VORSICHT Zum Auswechseln der Batterien das Ger t ausschalten ffnen Sie das Batteriefach Setzen Sie die neuen Batterien gem Abbildung ein Achten...

Страница 29: ...n ist rollierend die Werte erscheinen nacheinander in der Anzeige Um Druckspitzen zu messen wird die MIN MAX Funktion benutzt Im MIN MAX Speicher stehen die jeweils kleinsten MIN bzw gr ten MAX Messwe...

Страница 30: ...diese Anzeige auch im drucklosen Zustand nehmen Sie bitte Kontakt mit WIKA auf 6 2 8 Nullpunktkorrektur ZERO Bei unerw nschten Abweichungen im drucklosen Zustand Atmosph rendruck kann der Nullpunkt ma...

Страница 31: ...ration des Ger tes sind zwei verschiedene Anzeigen m glich Automatische Abschaltung Dauerbetrieb PO On Nach Bet tigen von erfolgt die automatische Abschaltung nach 5 min PO OFF Nach Bet tigen von muss...

Страница 32: ...der Filtereinstellungen D mpfung 2 s dr cken dr cken dr cken kurz dr cken Die Filterauswahl erscheint Filter 0 keine D mpfung Filter 3 hohe D mpfung Best tigen der Filtereinstellungen 6 2 13 Anzeige...

Страница 33: ...n bzw s ubern um Mitarbeiter und Umwelt vor Gef hrdung durch anhaftende Messstoffreste zu sch tzen Messstoffreste in dem ausgebauten Digitalmanometer CPG500 k nnen zur Gef hrdung von Personen Umwelt u...

Страница 34: ...g oder eine geeignete Transportverpackung verwenden Um Sch den zu vermeiden 1 Das Digitalmanometer CPG500 in eine antistatische Plastikfolie einh llen 2 Das Digitalmanometer CPG500 mit dem D mmmateria...

Страница 35: ...Notizen Notes WIKA Betriebsanleitung Typ CPG500 35 14034181 01 01 2013 GB D D Notizen Notes...

Страница 36: ......

Отзывы: