CDM Driver Error List
The following constants are defined by the CDM include files, and are available to your programs.
The ERROR codes report a non-recoverable error and require action to be taken before the process
can be continued. WARNINGS report conditions that usually indicate trouble.
Errors returned by the Drivers:
ERR_INVALID_ADDRESS
-1
Base address is out of range
ERR_CHANNEL_RANGE
-2
Channel number is out of range
ERR_AD_TIMEOUT
-3
A/D did not report EOC in time
ERR_NULL_POINTER
-4
Buffer pointer is not valid or NULL
ERR_NO_POINTS
-5
There are no points in the list to acquire
ERR_IRQ_RANGE
-6
The IRQ selected is out of range
ERR_BUFFER_OVERFLOW
-7
The values selected cause buffer overflow
ERR_BAD_MODE
-8
The mode selected is not defined
ERR_BAD_PARAMETER_LIST -9
An error occurred in the parameter list
ERR_PARAMETER 1
-10
Parameter #1 has an unknown error
ERR_PARAMETER 2
-11
Parameter #2 has an unknown error
ERR_PARAMETER 3
-12
Parameter #3 has an unknown error
ERR_PARAMETER 4
-13
Parameter #4 has an unknown error
ERR_PARAMETER 5
-14
Parameter #5 has an unknown error
ERR_PARAMETER 6
-15
Parameter #6 has an unknown error
ERR_PARAMETER 7
-16
Parameter #7 has an unknown error
ERR_PARAMETER 8
-17
Parameter #8 has an unknown error
ERR_PARAMETER 9
-18
Parameter #9 has an unknown error
ERR_PARAMETER 10
-19
Parameter #10 has an unknown error
ERR_USER_ABORT
-20
The user pressed a key, aborting the process
ERR_BAD_COUNTER
-21
The counter number is invalid
ERR_BAD_CORNER_FREQY
-22
The corner frequency selected is not possible
ERR_NOT_SUPPORTED
-23
Function not supported
Warnings returned by the drivers: (AAF = Only applies to AAF-series cards)
WARN_CAL_OUT_OF_RANGE 1
AAF The calibration value is so far out of range
that the card may be failing or is badly calibrated.
WARN_CAL_ABOVE_SCALE
2
AAF The offset calibration is >10% of FSV high
WARN_CAL_BELOW_SCALE
3
AAF The offset calibration is >10% FSV low
WARN_RATE_TOO_FAST
4
The sample rate is too fast for this process.
WARN_RATE_TOO_SLOW
5
The sample rate is too slow for this process.