ICPDAS TPD-283-H Скачать руководство пользователя страница 1

 

TPD-283-H 2.8” TouchPAD - QuickStart (Dec/2017)  

ICP DAS USA, Inc.

 | 

www.icpdas-usa.com

 | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717

 

 

 

 

 

TPD-283-H  

2.8'' High Speed Touch Screen HMI Controller  

Quick Start Guide 

Product Website:  

https://www.icpdas-usa.com/tpd_283_h.html

 

  

 

1. Introduction 

 

This quick start manual will guide users to implement the TPD-283-H module into 

their applications in a quick and easy way. This will only provide with the basic 
instructions. For the more detailed information, please refer to the TPD-283-H  user’s 
manual located on the ICPDAS CD-ROM or from ICP DAS web site

 

 

https://www.icpdas-usa.com/documents/user-manual-TPD-283-H.pdf

  

 

The ICP DAS TouchPAD is a tiny touch screen controller (electrical switch) HMI which 
is designed for building and home automation. TPD-283U-H is equipped with a high 
resolution TFT color touch screen and fits in regular electrical wall-mount outlets. 

                     

 

Содержание TPD-283-H

Страница 1: ... H module into their applications in a quick and easy way This will only provide with the basic instructions For the more detailed information please refer to the TPD 283 H user s manual located on the ICPDAS CD ROM or from ICP DAS web site https www icpdas usa com documents user manual TPD 283 H pdf The ICP DAS TouchPAD is a tiny touch screen controller electrical switch HMI which is designed for...

Страница 2: ...TPD 283 H 2 8 TouchPAD QuickStart Dec 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 2 2 Wirings ...

Страница 3: ...TPD 283 H 2 8 TouchPAD QuickStart Dec 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 3 ...

Страница 4: ...0 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 4 3 Install HMIWorks Follow the steps to install the HMIWorks 4 Setup Device Step1 Before downloading programs to the TPD 283U H be sure to setup TPD 283U H first Run HMIWorks_Standard exe and click on the menu Run Setup Device ...

Страница 5: ...art Dec 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 5 Step 2 In the Setup Ethernet device dialog box click the search for TouchPAD button to open search for TouchPAD dialog box ...

Страница 6: ...717 6 Step 3 If the TouchPAD device is found and displayed in the list on the Search for TouchPAD dialog box select the TouchPAD item depend on MAC Address of your TouchPAD device and click the OK button to bring the information back to the Setup Ethernet Device dialog box Note You can find the MAC address on the back of the TouchPAD ...

Страница 7: ...gnment Method field Notes 1 When using Static IP or DHCP the IP settings are stored as a part of the program image and only successful downloading can update the IP settings 2 When using Runtime Setting the program image has no information about the IP settings and TouchPAD loads the IP information from the flash at the runtime Before IP settings are used be sure to set the IP settings into the fl...

Страница 8: ... 200 Lomita CA 90717 8 Step 5 Verify that Host IP Address and TouchPAD IP Address in the same subnet Step 6 Verify that TouchPAD MAC Address must match the MAC Address of your TouchPAD device and click the OK button Note Verify that the new project has been created see Section 3 2 Create a New Project in the HMIWorks ...

Страница 9: ...arbonne Ave Suite 200 Lomita CA 90717 9 Step 7 Click the Run Build Download F9 item from the Run Build Download menu or press F9 Step 8 The Download in progress dialog box will be displayed showing the progress of the update Step 9 The TouchPAD device will then execute the string Hello TouchPAD sample ...

Отзывы: