ICPDAS iDS-718i-D Скачать руководство пользователя страница 1

Programmable Device Server User Manual (V

1

.1, Mar. 2020)  

 

- 1 -

 

Non-

Programmable Device Server 

User Manual 

 

 

 

iDS-718i-D 

Intelligent Device Server with 1 RS-232/422/485 (Isolated, RoHS, DB9) 

iDS-718iM-D CR 

Intelligent Device Server with 1 RS-232/422/485 (Isolated, Metal Case, RoHS, DB9) 

iDS-728i-T CR 

Intelligent Device Server with 2 RS-232/422/485 (Isolated, RoHS, Terminal block) 

iDS-728iM-T CR 

Intelligent Device Server with 2 RS-232/422/485 (Isolated, Metal Case, RoHS, Terminal block) 

iDS-448iM-D 

Intelligent Device Server with 4 RS-232/422/485 (Isolated, RoHS, DB9) 

 

Содержание iDS-718i-D

Страница 1: ...S DB9 iDS 718iM D CR Intelligent Device Server with 1 RS 232 422 485 Isolated Metal Case RoHS DB9 iDS 728i T CR Intelligent Device Server with 2 RS 232 422 485 Isolated RoHS Terminal block iDS 728iM T...

Страница 2: ...me without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents or other...

Страница 3: ...ONFIGURATION METHOD 19 2 4 1 Factory Setting 19 2 4 2 Setting IP Address 19 3 WEB MANAGEMENT INTERFACE 21 3 1 WEB BROWSER 21 3 2 INITIALIZE SETTING 22 3 2 1 Basic Setting 22 3 2 2 Network Setting 23 3...

Страница 4: ...ice Server User Manual V1 1 Mar 2020 4 4 3 1 TCP Server 35 4 3 2 TCP Client 36 4 3 3 UDP 37 4 4 PAIR CONNECTION 38 4 4 1 Pair Connection Server 38 4 4 2 Pair Connection Client 39 4 5 RFC2217 40 4 6 ET...

Страница 5: ...ardware serial number and real time clock etc These make the iDS Series becoming one of the most powerful system This device server is designed to add Ethernet and Internet connectivity to any RS 232...

Страница 6: ...ne Programmable Device Server hardware module One software utility CD One RS 232 console download cable CA 0903 One Quick Start Guide Note If any of these items are missed or damaged contact the local...

Страница 7: ...s in an Ethernet network Virtual COM for 32 bit and 64 bit Windows XP 2003 Vista 7 High performance ARM based Processor 256 MB DDR3 memory for data transmission and buffering Zero Data Loss UDP Suppor...

Страница 8: ...RTS and GND 8 wire RS 232 RxD TxD CTS RTS DCD DSR DTR and GND RS 422 485 TxD TxD RxD RxD and GND Data Data and GND RS 485 Data Data and Iso GND COM Port Formats Data Bits 5 6 7 8 Parity None Even Odd...

Страница 9: ...al Case RoHS DB9 iDS 728i T CR Intelligent Device Server with 2 RS 232 422 485 Isolated RoHS Terminal block iDS 728iM T CR Intelligent Device Server with 2 RS 232 422 485 Isolated Metal Case RoHS Term...

Страница 10: ...Programmable Device Server User Manual V1 1 Mar 2020 10 Unit mm 2 Getting Started 2 1 Dimensions and Mounting iDS Series...

Страница 11: ...Programmable Device Server User Manual V1 1 Mar 2020 11 Unit mm Fig 2 3...

Страница 12: ...Programmable Device Server User Manual V1 1 Mar 2020 12...

Страница 13: ...Programmable Device Server User Manual V1 1 Mar 2020 13 Unit mm Fig 2 4...

Страница 14: ...DIP Switch COM1 E1 E1 CON1 1 12 Terminal NO Pin Assignment E1 1 2 3 4 5 6 7 8 9 10 DC 12 48V 11 P PWR 12 P GND CON1 1 12 Pull high low resistors for the RS 422 RS 485 Port DIP Switch 1 2 3 4 5 6 7 8 R...

Страница 15: ...nual V1 1 Mar 2020 15 COM1 Pin Assignment Pin RS232 RS422 RS485 1 TXD Data 2 RXD TXD Data 3 TXD RXD 4 RXD 5 GND GND GND 6 7 RTS 8 CTS 9 DIP Switch COM1 Mode COM1 M1 M0 DIP Switch RS232 ON OFF RS422 OF...

Страница 16: ...V 48V 11 P PWR 12 P GND 1 18 CON2 1 12 CON2 1 18 Terminal NO Pin Assignment COM2 1 RS 422_RxD2 2 RS 422_RxD2 3 RS 422_TxD2 D2 4 RS 422_TxD2 D2 5 RS 232_CTS2 6 RS 232_RTS2 7 RS 232_RxD2 8 RS 232_TxD2 9...

Страница 17: ...Programmable Device Server User Manual V1 1 Mar 2020 17 2 2 3 iDS 448 Series E1 E2 CON1 1 6 Terminal NO Pin Assignment E1 E2 DC 12 48V 1 P PWR 2 P GND 3 P PWR 4 P GND 5 6 E1 E2 1 6 COM1 COM2 COM3 COM4...

Страница 18: ...lor Meaning PWR Red Power is on RUN Green OS is running Ethernet Green Ethernet Cable is connecting Table 2 1 DIP Switch COM1 4 Mode COM1 M1 M0 DIP Switch RS232 ON OFF RS422 OFF ON RS485 OFF OFF Softw...

Страница 19: ...8 255 254 Protocol icpdas protocol 2 4 2 Setting IP Address Using web browser IE or Chrome and typing the default IP 192 168 255 1 to connect to the iDS devices to set IP address DHCP or Static Please...

Страница 20: ...Programmable Device Server User Manual V1 1 Mar 2020 20 Fig 2 6 Network Set IP Information 2 1 3 Click save button to save the setting Click Network...

Страница 21: ...IE 8 or later version Chrome to operate the iDS 700 series web management interface User can input the IP address to connect to the login interface of iDS 700 device Please refer to the Fig 3 1 Fig 3...

Страница 22: ...2 1 Basic Setting Clicking the Basic Setting to set the iDS s hostname or enable disable the function UDP search the system default don t enable Please refer to the Fig 3 2 Fig 3 2 Basic Setting 1 Set...

Страница 23: ...erver User Manual V1 1 Mar 2020 23 3 2 2 Network Setting Clicking the Network to set the IP address Please refer to the Fig 3 3 Fig 3 3 Network Set IP Information 2 1 3 Click Save button to save the s...

Страница 24: ...Device Server User Manual V1 1 Mar 2020 24 3 2 3 SNMP Clicking the SNMP to set the SNMP Agent Please refer to the Fig 3 4 Fig 3 4 SNMP 1 Click SNMP Set SNMP Configuration 2 3 Click Save button to save...

Страница 25: ...5 3 2 4 Account Password Table Clicking the Account Password Table to set the account information Please refer to the Fig 3 5 Fig 3 5 Account Password Table 1 3 Set account information 2 Click Save bu...

Страница 26: ...26 3 2 5 Accessible IP Table Clicking the Accessible IP Table to enable disable the rules of IP filter Please refer to the Fig 3 6 Fig 3 6 Accessible IP Table 1 Click Edit 2 Enable Disable IP filer 3...

Страница 27: ...2020 27 3 2 6 Monitor Clicking the Line Async Async Setting to get the COM s information Please refer to the Fig 3 7 and Fig 3 8 Fig 3 7 Async Fig 3 8 Async Setting 1 Get COM s information 2 1 Get COM...

Страница 28: ...nction of events notification and inform the system administrator Please refer to the Fig 3 9 Fig 3 10 Fig 3 9 Events Fig 3 10 Email SNMP Trap 1 Set the method of notification 2 3 1 Set the network en...

Страница 29: ...to the Fig 3 11 Fig 3 11 Firmware upgrade 3 2 9 Restart Clicking the Restart to reboot the iDS 700 module Please refer to the Fig 3 12 Fig 3 12 Restart 1 2 Please choose the icpdas s firmware package...

Страница 30: ...king the SERIAL PORT SETTING Port1 to set the serial port s basic configuration or click the SERIAL PORT SETTING Advanced Options to set the serial port s modem control and command setting Please refe...

Страница 31: ...Programmable Device Server User Manual V1 1 Mar 2020 31 Fig 4 2 Port1 s Advanced Option 1 Click Port1 s Advanced Options Set Port s Advanced Options 2 3 Click Save button to save the setting...

Страница 32: ...ling Virtual COM Utility Please install VxComm Utility v 2 12 07 or later version the software can download from below web link http ftp icpdas com pub cd 8000cd napdos driver vxcomm_driver 4 2 2 Netw...

Страница 33: ...on the desktop 2 Click the Add Server s button to connect to the iDS 700 then user assign a COM Port number and click OK to save your settings please refer to Fig 4 3 Fig 4 3 3 Click on iDS 700 s name...

Страница 34: ...able Device Server User Manual V1 1 Mar 2020 34 4 Click Tools Restart Driver and then click the Restart Driver button please refer to Fig 4 5 Fig 4 5 1 Click Tools Restart Driver 2 Click Restart Drive...

Страница 35: ...ck DEVICE SERVER Port1 to choose TCP Server mode please refer to Fig 4 6 After user had saved the setting user must reboot iDS modules please refer to the chapter 3 2 9 restart Fig 4 6 TCP Server Mode...

Страница 36: ...t mode please refer to Fig 4 7 After user had saved the setting user must reboot iDS modules please refer to the chapter 3 2 9 restart Fig 4 7 TCP Client Mode 1 Click Port1 2 Choose TCP Server 3 4 Set...

Страница 37: ...DP mode please refer to Fig 4 8 After user had saved the setting user must reboot iDS modules please refer to the chapter 3 2 9 restart Fig 4 8 UDP Mode 1 Click Port1 2 Choose UDP 3 Set iDS s port num...

Страница 38: ...CE SERVER Port1 to choose Pair Connection mode please refer to Fig 4 9 After user had saved the setting user must reboot iDS modules please refer to the chapter 3 2 9 restart Fig 4 9 Pair Connection S...

Страница 39: ...ease refer to Fig 4 10 After user had saved the setting user must reboot iDS modules please refer to the chapter 3 2 9 restart Fig 4 10 Pair Connection Client 1 Click Port1 6 Click Save button to save...

Страница 40: ...DEVICE SERVER Port1 to choose RFC 2217 mode please refer to Fig 4 10 After user had saved the setting user must reboot iDS modules please refer to the chapter 3 2 9 restart Fig 4 10 1 Click Port1 2 Ch...

Страница 41: ...thernet Modem mode please refer to Fig 4 11 After user had saved the setting user must reboot iDS modules please refer to the chapter 3 2 9 restart Fig 4 11 Ethernet Modem 1 Click Port1 2 Choose Ether...

Отзывы: