2.5 Hardware Installation
When users want to use the PISO-DNS100(U)-D/T board, the hardware
installation needs to be finished as following steps.
PISO-DNS100(U) DeviceNet Slave API functions User’s Manual (Ver: 1.1) 2010/01/07
24
1. Shutdown your personal computer.
2. Configure the DIP switch and JP1 of your PISO-DNS100(U)-D/T for board
No. and terminal resistance. More detail information could be found on the
figure 2.1 and table 2.1.
3. Check JP3 status of PISO-DNS100(U)-D/T. If necessary, enable it.
4. Find an empty PCI slot for your PISO-DNS100(U)-D/T on the mother board
of the personal computer. Plug the configured PISO-DNS100(U)-D/T into this
empty PCI slot. See figure 2.5.1.
5. Plug your CAN bus cable(s) into the 5-pin screw terminal connector or the 9-
pin D-sub connector.
When the steps described above is completed, turn on the personal computer.
Figure 2.5.1 PISO-DNS100(U) installation