PISO-CPM100(U) / PCM-CPM100 user manual (ver. 2.02) Dec/03/2012 ----------------- 61
4.5.27. CPM100_SDOAbortTransmit
Description:
Call the function CPM100_SDOAbortTransmit to cancel the SDO
transmission. The parameter node of this function is used to specify
which SDO communication will be terminated between the master and
the specified salve device.
Syntax:
WORD
CPM100_SDOAbortTransmit(
BYTE
BoardNo,
BYTE
Node,
WORD
Index,
BYTE
SubIndex,
DWORD
*AData,
BYTE
BlockMode)
Parameter:
BoardNo:
[input] CPM100 board number (0~7).
Node:
[input] Slave device Node-ID (1~127).
Index
: [input] The object index value of the object dictionary.
SubIndex:
[input] The object subindex value of the object dictionary.
*AData:
[input] Abort data to be send to slave.
BlockMode:
[input] 0 means this function is non-block-function, and 1
means this function is block-function. If set this parameter to 1, the
running procedure of the users’ application will be held in the
function until return. If set to 0, this function will return “CPM_
Processing” directly. This function will return its process status
while users apply it with the same “BoardNo” and “Node” again. If
the procedure is still not complete, it will return “CPM_Wait”.