PEX/PIO/PISO-DA Series Card
Analog Output Boards
User Manual/ Ver. 3.1/ Oct. 2013/ PMH-0010-31/ Page: 6
1.
Introduction
The PEX-DA, PISO-DAxU and PIO-DAxU series cards (PCI Express/Universal PCI versions) are
compatible with the PIO-DAx cards (PCI versions) and most users can replace the PIO-DAx by PEX-DA,
PISO-DAxU or PIO-DAxU directly without software/driver modification. Please refer to user manual
(ch 1.1) for the compatibility information.
The PISO-DA series adds high-voltage isolation design that offers a durable ability to keep users'
computers safe from unexpected surge. It is the built-in high-quality isolation components that make
PISO-DA series featuring 2500 V
DC
bus-typed isolation! For the PEX-DA, PIO-DA and the PISO-DA
series, their voltage output range is from -10 V to +10 V, and their current output range is from 0 to
20 mA. In addition, These cards also feature the following advantages by ICP DAS's innovation:
1.
Accurate and easy-to-use calibration.
ICP DAS provides the software calibration instead of the manual calibration so that no jumpers
and trim-pots are required anymore. The calibration information can be saved in EEPROM for
long-term use.
2.
Individual channel configuration.
In other words, every channel can be individually configured as voltage output or current
output!
3.
Card ID.
ICP DAS provides the card ID function for PEX-DA, PISO-DAxU and PIO-DAxU (version 1.1 or
above) series. Users can set card ID for each card and then recognize them one by one when
more than two boards are used in a computer.
Note: This card needs a
12 V power supply, which can be found in either a
regular PC or an Industrial PC.