IR-310-RM,
IR Controlled 10-ch High Power Relay Module
(Ver. 1.1, Jul/02/2013) 17
2.8 DIP Switch
There four states of the 2-pin dip switch which represent four modes for IR-310-RM as
shown in table 2-5. To take effect the setting, please power cycle the module after set
the dip switch.
Table 2-5: Four states of dip switch.
(1) Normal Mode
The mode except other three modes.
(2) Sequential mode
In this mode, the 10 relay can be switch forward to NO or backward to NC
sequentially.
(3) Init mode
In this initialization mode, IR-310-RM always use the default communication
settings.
Table 2-5 Default communication settings
Item
Default value
Baud Rate
9600 bps
Parity/Databits/Stopbtis
None/8/1
Modbus Net ID
1
(4) Emitting built-in IR commands mode (corresponding to built-in IR-Relay-States)
Built-in IR commands are the IR commands corresponding to the built-in 10 relay
states (Refer to appendix A). In this mode, IR-310-RM will emit IR commands #192
~ #203 sequentially from the IR output channel. The flowchart of this process is
depicted in figure 2-16. Users can set the IR learning remote control in the learning
mode to learn these IR commands for test as shown in figure 2-17.