background image

 

 

GRP-530M / GRP-540M User Manual 

Version 1.2.1 

Page

81 

 

Copyright ©  2017 ICP DAS Co., Ltd. All Rights Reserved    E-mail: [email protected] 

 

 

 

 

 

 

 

 

Содержание GRP-540M Series

Страница 1: ...User Manual Version 1 2 1 February 2019 GRP 530M GRP 540M Serial 3G 4G Gateway Written by Shepard Lee Edited by Kalia Huang...

Страница 2: ...dicators 12 2 6 Rotary Switch 12 2 7 Installing Device 13 3 Web Utility 15 3 1 Login the Utility 15 3 2 Information 16 3 2 1 Device Information 16 3 2 2 Network Information 17 3 2 3 Storage Informatio...

Страница 3: ...Test 39 3 6 4 Modbus Test 40 3 7 RTU CAN Client 41 3 7 1 Basic Configure 41 3 7 2 CAN Configure 42 3 7 3 FTP Email 43 4 Example 45 4 1 3G 4G Router Application 45 4 2 Web Server and IP Camera Applica...

Страница 4: ...right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not for...

Страница 5: ...eway for Ethernet or serial port With GPS function it can also be a GPS tracking system It can be used in M2M application fields to transfer the remote I O Modbus data or video of the camera via 3G 4G...

Страница 6: ...M 4GX WF 10 100 Base TX compatible Ethernet controller COM port COM1 3 wire RS232 COM2 3 wire RS232 COM3 RS 485 Support CAN GPS 32 channels with All In View tracking option Support Micro SD card Provi...

Страница 7: ...Manual Version 1 2 1 Page 7 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Application 1 3G 4G Router Application 2 Remote Video Monitor Application 3 Remote Control Seria...

Страница 8: ...Serial Number Yes Watchdog Timer Yes LED Indicator 4 LEDs RUN PWR 3G L1 L2 Rotary Switch Yes 0 9 GSM System Frequency Band GSM 850 900 1800 1900 MHz GPRS connectivity GPRS class 12 GPRS station class...

Страница 9: ...xpansion Flash Memory SD Card Max 32GB SDHC RTC Real Time Clock Provide seconds minutes hours day of week month month and year 64 bit Hardware Serial Number Yes Watchdog Timer Yes LED Indicator 4 LEDs...

Страница 10: ...TxD and GND Non isolated Console Debug COM2 RS 232 RxD TxD and GND Non isolated COM3 RS 485 D2 D2 3000 VDC isolated CAN CAN Bus CAN_H CAN_L Mechanism Casing Metal Dimensions W x L x H 117 mm x 126 mm...

Страница 11: ...2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com COM Port Power Input Terminal No Pin Assignment Power 14 F G 13 P GND 12 PWR COM1 11 TxD1 10 RxD1 09 GND COM2 08 TxD2 07 RxD2 06 GND C...

Страница 12: ...Fail Heart beat 1 sec Always ON or OFF C L1 Green Red this Led indicates the status of RTU Client Normal Fail 500ms ON 500ms OFF Always ON or OFF D L2 Green Red reserve E 3G Red The LED indicates the...

Страница 13: ...If you want to use the Micro SD card please insert it into the slot E Connect the DC VS and DC GND to the power supply F It is needed to wait about 20 30 seconds for OS booting After finishing the pr...

Страница 14: ...GRP 530M GRP 540M User Manual Version 1 2 1 Page 14 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Страница 15: ...ce icpdas com 3 Web Utility You must configure the device from web utility before using 3 1 Login the Utility Please login before you use the web utility The default username is admin and the default...

Страница 16: ...ved E mail service icpdas com 3 2 Information You can get the basic information of the device here 3 2 1 Device Information This page provides basic device information 1 Product Name the Name of your...

Страница 17: ...mation This page provides basic network information 1 Ethernet Ethernet information Mode static IP MAC address a unique identifier assigned to network interfaces IP Address a computer s address under...

Страница 18: ...which method to get IP address Please refer to below Static user can set IP address Mask and Gateway by himself DHCP get IP address Mask and Gateway from AP s DHCP server IP Address the station s addr...

Страница 19: ...of SIM card SIM PUK need PUK code of SIM card SIM failure Access SIM Card failure Register Status Indicating machine connect to mobile network successful or not Signal Quality the 3G 4G signal qualit...

Страница 20: ...3 Network The user can configure the Network functions here 3 3 1 Ethernet This page provides the basic settings of Ethernet 1 IP Address IP of Ethernet 2 Mask the Mask of the gateway 3 Gateway IP of...

Страница 21: ...or WPA2 PSK security mode 7 Password if use WPA2 PSK need to set password for 8 64 characters Station Mode 1 AP s SSID the name of remote Wi Fi AP 2 AP s Password the password of remote Wi Fi AP 3 IP...

Страница 22: ...ts Reserved E mail service icpdas com 3 3 3 PIN APN Configure This page provides basic settings of 3G 4G network GRP 530M GRP 540M GRP 541M 1 PIN Code PIN Code are 4 character number provided by SIM C...

Страница 23: ...ction This function can keep the device always on mobile network but it will send the IMCP signals to check mobile network The default setting is Enable to keep device always online 1 Server IP the ta...

Страница 24: ...thod of updating in real time a Domain Name System DNS to point to a changing IP address on the Internet 1 Server the address of DDNS service provider 2 Domain The domains name you registered 3 Userna...

Страница 25: ...v1 2 1 User can set VPN with PPTP protocol and use DDNS or FTP to get the VPN IP 1 VPN Server the address of VPN service provider 2 VPN Username the username of VPN service 3 VPN Password the passwor...

Страница 26: ...rd the password of FTP service 5 FTP File Name the file in the server to save your address 6 FTP Period the period time seconds to update your address 7 FTP Passive Mode enable the passive mode 3 3 8...

Страница 27: ...the protocol type There are TCP and UDP 2 From the interface that the socket comes from ppp0 is 3G interface 3 Port the port that the socket comes from 4 Target IP the IP that the socket goes forward...

Страница 28: ...the problem of the network 1 Ping Test this tool will ping Target IP and show result below 2 Traceroute this tool will trace routing path to Target IP and show the result below 3 Route Information th...

Страница 29: ...e device and restore factory settings here 3 4 1 Password The user can change the password of the web utility here 1 Password new password 2 Confirm confirm the password again 3 4 2 Reboot The user ca...

Страница 30: ...ngs into your PC 2 Restore Press Browse button to select file and then press Restore button to store your settings 3 4 5 Update only support the firmware after v1 2 1 The user can update the device s...

Страница 31: ...ovide information about the time of the device 1 Set Time set the time of device the same as your computer 2 NTP Server device will connect to the NTP Server to synchronize time 3 Timezone if you do n...

Страница 32: ...e 3 5 1 VxServer The user can configure VxServer firmware here 1 Server IP Server IP or URL 2 Server Port the port of the server 3 Heartbeat Time if setting this value small it is sensitive to detect...

Страница 33: ...s over this value the data will be sliced into two packets Usually you just set this value as 1000 if you don t need this function this value is limited by network protocol 8 Modbus TCP to RTU Modbus...

Страница 34: ...ient The user can configure RTU Client firmware function here There are three tabs 1 Main Info 2 Modbus Number 3 FTP Email Main Info Tab 1 Server Address Server IP or Domain Name 2 Server Port the por...

Страница 35: ...early Heartbeat Period must be smaller than Data Update Period 6 Baud Rate RS 485 for Modbus RTU the baud rate of the RS 485 COM3 7 Data bit the data bit of RS 485 8 Parity the parity bit of RS 485 9...

Страница 36: ...and then use the Add button to add a new modbus device 2 Device Name the Name of the modbus device This Name will be showed in RTU Center 3 Device ID the modbus ID 4 IP the IP of modbus TCP device Kee...

Страница 37: ...ddress the start address for reading AO value FTP Email This function will send back all I O data log file automatically The period time to send is depending on Max Time per Log File hour parameter 1...

Страница 38: ...login 6 FTP password password for login 7 Enable FTP Function enable FTP report function 8 Email From the email will be sent from this address 9 Email To the email address that will receive logger fil...

Страница 39: ...email will be sent from this address 2 Email To the email address that will receive logger file Using to separate each mail address Example for single receiver xxx gmail com for multi receiver xxx gma...

Страница 40: ...r Manual Version 1 2 1 Page 40 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 6 4 Modbus Test The user can test all configure for Modbus here There is the result message...

Страница 41: ...ient firmware function here 1 Server Address Server IP or Domain Name 2 Server Port the port of the server 3 Station ID the ID for this device do not be the same with other RTU device 4 Data Update Pe...

Страница 42: ...he RTU function 1 CAN Baud Rate configure baud rate here 2 Group there are 10 group in RTU function the user can configure CAN data a byte fill to the ai point that you choose 3 ai index a group have...

Страница 43: ...data to logger file Set as 0 to disable all function in this tab 2 Max Time per Log File min the time interval to change log file and send log file via Email or FTP it will change logger file before...

Страница 44: ...sent from this address 9 Email To the email address that will receive logger file Using to separate each mail address Example for single receiver xxx gmail com for multi receiver xxx gmail com yyy gm...

Страница 45: ...d All Rights Reserved E mail service icpdas com 4 Example 4 1 3G 4G Router Application This example shows the steps to share 3G 4G network to 3 XPac8000 1 Please configure the Ethernet of XPac8000 as...

Страница 46: ...need it Press Modify to save 4 Enable Network Reconnection function to keep your mobile network always online usually ISP will disconnect your connection once every 1 3 days Generally you can set the...

Страница 47: ...pyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 Set routing rule to share 3G 4G network This setting will share 3G network to IP address from 192 168 0 1 192 168 0 255 Pres...

Страница 48: ...l service icpdas com 4 2 Web Server and IP Camera Application This example shows the steps to share 3G 4G network to ET 7044 and IP camera 1 Please Set the Ethernet of ET 7044 and IP camera as IP 192...

Страница 49: ...ard needs it Press Modify 4 Enable Network Reconnection function to keep your mobile network always online usually ISP will disconnect your connection once every 1 3 days Generally you can set the Ser...

Страница 50: ...et user access the device behind GRP device via the internet This setting will bind the port of 3G interface to Target IP Target Port Port 12080 of 3G interface 192 168 0 20 80 Port 12180 of 3G interf...

Страница 51: ...icpdas com 7 Please type the IP address or domain name of GRP device in 3G 4G network You will look as below It maybe like mygrp5k no ip org 12080 8 If you want to see the IP Camera image from web bro...

Страница 52: ...ial port to 3G 4G gateway function 1 Please connect your device DL 100 or PLC to serial port of GRP device 2 If you never use VxServer please refer the link as below http m2m icpdas com VxServer html...

Страница 53: ...days Generally you can set the Server IP as your server s IP or Google s DNS server IP 8 8 8 8 If you use MDVPN please set the Server IP as your Server IP that doesn t deny ICMP service Ping Press Mo...

Страница 54: ...1 2 1 Page 54 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 Please reset your device and un plug your Ethernet from GRP device it will dial up in 60 seconds and then i...

Страница 55: ...ice connect to VxServer please follow steps below a Press Search Servers button you will get a device list b Click right button of the mouse on GRP 520_GRP 530 c Click Add Server d Choose the virtual...

Страница 56: ...GRP 530M GRP 540M User Manual Version 1 2 1 Page 56 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Страница 57: ...DAS Co Ltd All Rights Reserved E mail service icpdas com 8 You will see virtual com port COM32 COM33 but it can t be opened Click tool Restart Driver to restart VxComm driver Open com port to connect...

Страница 58: ...er Port 10001 is RS 232 Port 10002 is RS 485 1 Please connect your device M 7017 or PLC to RS 485 of GRP device Baudrate of Modbus device is 9600 bps data format is 8N1 Data bits Parity Stop bits Baud...

Страница 59: ...ection function to keep your mobile network always online usually ISP will disconnect your connection once every 1 3 days Generally you can set the Server IP as your server s IP or Google s DNS server...

Страница 60: ...m 5 Configure VxServer Function Set Server IP and Server Port the default port number is 11000 For Card Reader Please just set Port1 RS 232 as default value For Modbus RTU device Port2 RS 485 Please c...

Страница 61: ...un plug your Ethernet from GRP device it will dial up in 60 seconds and then it will connect to your control center 7 After GRP device connect to VxServer please follow steps below a Press Search Serv...

Страница 62: ...mail service icpdas com 8 You will see virtual com port COM32 COM33 but it can t be opened Click tool Restart Driver to restart VxComm driver Open com port to connect your device In this case COM32 is...

Страница 63: ...td All Rights Reserved E mail service icpdas com 4 5 RTU Client for Remote Control Application with RTU API This example shows how to use RTU API to collect and control remote Modbus RTU and Modbus TC...

Страница 64: ...ver use RTU Center please refer the link as below http m2m icpdas com m2m_rtu html If you need OPC solution please refer the link as below http m2m icpdas com NAPOPC_M2M html If you need RTU library t...

Страница 65: ...always online usually ISP will disconnect your connection once every 1 3 days Generally you can set the Server IP as your server s IP or Google s DNS server IP 8 8 8 8 If you use MDVPN please set the...

Страница 66: ...Co Ltd All Rights Reserved E mail service icpdas com 6 The web will bring out all I O number information as below Please modify Device Name Device ID IP and Port for your ET 7050 Device Name an alias...

Страница 67: ...creenshot as below The web will bring out all I O number information Please modify Device Name and Device ID for your M 7022 Don t modify IP and Port settings Press Modify to add a device 8 Add PLC in...

Страница 68: ...ce icpdas com 9 Three devices we set as below 10 Please choose Modbus Test function and press Test button to test our settings If the result is successful the screenshot will be as below and please fo...

Страница 69: ...rved E mail service icpdas com 11 Configure Main Info Tab Set Server Address and Server Port of your server that running RTU Center Set Station ID and don t be the same with another RTU device Set Dat...

Страница 70: ...and then extract RTU Center Or you can install NAPOPC M2M DA Server it contains RTU Center Please download install file from http m2m icpdas com NAPOPC_M2M html 13 Execute RTU Center and add a RTU dev...

Страница 71: ...Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 14 GRP device will connect to RTU Center later and screenshot as below 15 You can double click on ET 7050 to bring out Outp...

Страница 72: ...al Version 1 2 1 Page 72 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 16 Download RTU API from RTU Center web page and extract it There are RTU API library and some demo...

Страница 73: ...o Ltd All Rights Reserved E mail service icpdas com 17 Copy pre building demo into folder of RTU Center demo must be in the same folder with RTU Center because they use the same share memory in M2M_RT...

Страница 74: ...ess Get Information to get all stations information Set Station ID as 1 because we set Station ID as 1 in GRP device Press 2 ReadData button to read Local IO data Because GRP device don t have local I...

Страница 75: ...s com 4 6 RTU Client for Remote Control Application with OPC DA Server 1 Please refer last section for setting of RTU Client RTU Center 2 After install NAPOPC M2M DA Server please click the icon to la...

Страница 76: ...AS Co Ltd All Rights Reserved E mail service icpdas com 4 You will get a tag list as below 5 You can double click on device node to modify device name 6 Now you can use OPC Client to read I O data fro...

Страница 77: ...il service icpdas com 4 7 RTU Client for Remote Control Application with InduSoft This example shows how to using SCADA InduSoft to control monitor remote I O with GRP device 1 About RTU Client RTU Ce...

Страница 78: ...ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 Choice OPC Server from Server Identifier and Select NAPOPC M2M Item from combo box 4 Configure Tag Name and Item Column Fill in your tag...

Страница 79: ...ord IO data into csv file 0 disable filename format GRP 530_StationID_YYYYMMDD_hhmmss csv ex GRP 530_13_20140806_172347 csv Configure Max Time per Log File to indicate how long to change send back log...

Страница 80: ...1 Page 80 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 Finally please don t forget enable firmware in Main Info Tab If you don t need the firmware send data to RTU Ce...

Страница 81: ...GRP 530M GRP 540M User Manual Version 1 2 1 Page 81 Copyright 2017 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Страница 82: ...tory Version Date Description of changes 1 0 0 2015 11 05 The First Release Revision 1 1 1 2016 10 26 New feature GPS Function 1 1 3 2016 11 21 Add 4G version GRP 540M 4GE 1 1 4 2017 01 11 Add DDNS Fu...

Отзывы: